Release 5 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v5.0.0: R5 - STU ). This is the current published version in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Procedure/example-implant (Narrative)

Maturity Level : N/A
Responsible Owner: Patient Care Work Group Standards Status : Informative Compartments : Encounter , Group , Patient , Practitioner , RelatedPerson

This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Procedure .


Generated Narrative: Procedure example-implant

Resource Procedure "example-implant"

status : completed Completed

code : Implant Pacemaker ( SNOMED CT #25267002 "Insertion of intracardiac pacemaker (procedure)")

subject : Patient/example Jim Male, DoB: 1974-12-25 ( Medical record number (use: usual, period: 2001-05-06 --> (ongoing))) "Peter CHALMERS"

occurrence : 2015-04-05

Performers

- Actor
* Practitioner/example: Dr Cecil Surgeon "Adam CAREFUL"

Reasons

- Concept
* Bradycardia ()

FollowUps

- followUp : Concept
* ROS 5 days - 2013-04-10 ()

note :

Routine Appendectomy. Appendix was inflamed and in retro-caecal position

FocalDevices

- Action Manipulated
* Implanted ( Procedure Device Action Codes #implanted) Device: manufacturer = Acme Devices, Inc; lotNumber = 1234-5678; type = Cardiac pacemaker, device (physical object)

Generated Narrative: Device #example-pacemaker

manufacturer : Acme Devices, Inc

lotNumber : 1234-5678

type : Cardiac pacemaker implant ( SNOMED CT #14106009) pacemaker, device (physical object)


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.