Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4 R3

Procedure-example-ambulation.json

Example Procedure/ambulation (JSON)

Maturity Level : N/A
Responsible Owner: Patient Care Work Group Standards Status : Informative Compartments : Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Example of ambulation procedure

{
  "resourceType": "Procedure",
  "id": "ambulation",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">Ambulation procedure was not done</div>"

  "resourceType" : "Procedure",
  "id" : "ambulation",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Ambulation procedure was not done</div>"

  },
  "identifier": [
    {
      "value": "12345"
    }
  ],
  "instantiatesUri": [
    "http://example.org/protocol-for-hypertension-during-pregnancy"
  ],
  "basedOn": [
    {
      "reference": "CarePlan/preg",
      "display": "Maternity care plan"
    }
  ],
  "status": "not-done",
  "statusReason": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "398254007",
        "display": "  Pre-eclampsia (disorder)"
      }
    ],
    "text": "Pre-eclampsia"

  "identifier" : [{
    "value" : "12345"
  }],
  "basedOn" : [{
    "reference" : "CarePlan/preg",
    "display" : "Maternity care plan"
  }],
  "status" : "not-done",
  "statusReason" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "398254007",
      "display" : "Pre-eclampsia (disorder)"
    }],
    "text" : "Pre-eclampsia"

  },
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "62013009",
        "display": "Ambulating patient (procedure)"
      }
    ],
    "text": "Ambulation"

  "code" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "62013009",
      "display" : "Ambulating patient (procedure)"
    }],
    "text" : "Ambulation"

  },
  "subject": {
    "reference": "Patient/example"

  "subject" : {
    "reference" : "Patient/example"

  },
  "performer": [
    {
      "actor": {
        "reference": "Practitioner/f204",
        "display": "Carla Espinosa"
      },
      "onBehalfOf": {
        "reference": "Organization/f001",
        "display": "University Medical Hospital"
      }

  "performer" : [{
    "actor" : {
      "reference" : "CareTeam/example",
      "display" : "Maternity CareTeam"
    },
    "onBehalfOf" : {
      "reference" : "Organization/f001",
      "display" : "University Medical Hospital"

    }
  ],
  "location": {
    "reference": "Location/1",
    "display": "Burgers University Medical Center, South Wing, second floor"

  }],
  "location" : {
    "reference" : "Location/1",
    "display" : "Burgers University Medical Center, South Wing, second floor"

  },
  "reasonReference": [
    {
      "reference": "Observation/blood-pressure",
      "display": "Blood Pressure"

  "reason" : [{
    "reference" : {
      "reference" : "Observation/blood-pressure",
      "display" : "Blood Pressure"

    }
  ]

  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.