Conformance
This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v5.0.0:
R5
-
STU
).
This
is
the
current
published
version
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
| Responsible Owner: Terminology Infrastructure Work Group | Standards Status : Informative |
Raw XML ( canonical form + also see XML Format Specification )
Operation Definition
<?xml version="1.0" encoding="UTF-8"?> <OperationDefinition xmlns="http://hl7.org/fhir"> <id value="NamingSystem-preferred-id"/> <text><status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p class="res-header-id"> <b> Generated Narrative: OperationDefinition NamingSystem-preferred-id</b> </p> <a name="NamingSystem-preferred-id"> </a> <a name="hcNamingSystem-preferred-id"> </a> <p> URL: [base]/NamingSystem/$preferred-id</p><h3> Parameters</h3> <table class="grid"> <tr> <td> <b> Use</b> </td> <td> <b> Name</b> </td> <td> <b> Scope</b> </td> <td> <b> Cardinality</b> </td> <td> <b> Type</b> </td> <td> <b> Binding</b> </td> <td> <b> Documentation</b> </td> </tr> <tr> <td> IN</td> <td> id</td> <td/> <td> 1..1</td> <td> <a href="datatypes.html#string">string</a> </td> <td/> <td> <div> <p> The server parses the provided identifier to see what type it is (e.g. a URI, an OID as a URI, a plain OID, or a v2 table 0396 code). If the server can't tell what type of identifier it is, it can try it as multiple types. It is an error if more than one system matches the provided identifier</p> </div> </td> </tr> <tr> <td> IN</td> <td> type</td> <td/> <td> 1..1</td> <td> <a href="datatypes.html#code">code</a> </td> <td> <a href="valueset-namingsystem-identifier-type.html">Naming System Identifier Type</a> (Required) </td> <td/> </tr> <tr> <td> IN</td> <td> date</td> <td/> <td> 0..1</td> <td> <a href="datatypes.html#dateTime">dateTime</a> </td> <td/> <td> <div> <p> If specified, the operation will indicate what the preferred identifier was on the specified date. If not specified, the operation will provide the preferred identifier as of 'now'</p> </div> </td> </tr> <tr> <td> OUT</td> <td> result</td> <td/> <td> 1..1</td> <td> <a href="datatypes.html#string">string</a> </td> <td/> <td> <div> <p> OIDs are return as plain OIDs (not the URI form).</p> </div> </td> </tr> </table> <div> <p> Servers handle this request by finding the provided identifier in their known naming systems, and returning the requested identifier type ( <a href="namingsystem-definitions.html#NamingSystem.uniqueId.type">NamingSystem.uniqueId.type</a> ). If there is more than one identifier of the specified type (for the specified date), then the 'preferred' identifier will be returned. If there is only one identifier, that identifier will be returned even if it is not preferred. If there are multiple preferred identifiers or multiple identifiers with none marked as preferred, the system MAY return an error or may list all identifiers applicable for that date and period. </p> <p> If the server wishes, it can also look through all code systems and value sets it knows about when attempting to find the requested identifier.</p> </div> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="1"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"><valueCode value="normative"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="vocab"/> </extension> <url value="http://hl7.org/fhir/OperationDefinition/NamingSystem-preferred-id"/><version value="6.0.0-ballot3"/> <name value="PreferredId"/> <title value="Fetch Preferred id"/><status value="active"/> <kind value="operation"/> <experimental value="false"/><date value="2025-11-24T20:46:00+00:00"/> <publisher value="HL7 International / Terminology Infrastructure"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org/fhir"/> </telecom> <telecom> <system value="email"/> <value value="fhir@lists.hl7.org"/> </telecom> </contact> <contact> <telecom> <system value="url"/> <value value="http://www.hl7.org/Special/committees/Vocab"/> </telecom> </contact> <description value="This operation returns the preferred identifiers for identifiers, and terminologies. The operation takes 2 parameters: * a system identifier - either a URI, an OID, or a v2 table 0396 (other) code * a code for what kind of identifier is desired (URI, OID, v2 table 0396 identifier) and returns either the requested identifier, or an HTTP errors response with an OperationOutcome because either the provided identifier was not recognized, or the requested identiifer type is not known. The principle use of this operation is when converting between v2, CDA and FHIR Identifier/CX/II and CodeableConcepts/C(N/W)E/CD but the operation may also find use when converting metadata such as profiles."/> <jurisdiction> <coding> <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/> <code value="001"/> <display value="World"/> </coding> </jurisdiction> <affectsState value="false"/> <code value="preferred-id"/> <comment value="Servers handle this request by finding the provided identifier in their known naming systems, and returning the requested identifier type ([NamingSystem.uniqueId.type](namingsyst em-definitions.html#NamingSystem.uniqueId.type)). If there is more than one identifier of the specified type (for the specified date), then the 'preferred' identifier will be returned. If there is only one identifier, that identifier will be returned even if it is not preferred. If there are multiple preferred identifiers or multiple identifiers with none marked as preferred, the system MAY return an error or may list all identifiers applicable for that date and period. If the server wishes, it can also look through all code systems and value sets it knows about when attempting to find the requested identifier."/> <resource value="NamingSystem"/> <system value="false"/> <type value="true"/> <instance value="false"/> <parameter> <name value="id"/> <use value="in"/> <min value="1"/> <max value="1"/> <documentation value="The server parses the provided identifier to see what type it is (e.g. a URI, an OID as a URI, a plain OID, or a v2 table 0396 code). If the server can't tell what type of identifier it is, it can try it as multiple types. It is an error if more than one system matches the provided identifier"/> <type value="string"/> </parameter> <parameter> <name value="type"/> <use value="in"/> <min value="1"/> <max value="1"/> <type value="code"/> <binding> <extension url="http://hl7.org/fhir/StructureDefinition/elementdefinition-bindingName"> <valueString value="NamingSystemIdentifierType"/> </extension> <strength value="required"/><valueSet value="http://hl7.org/fhir/ValueSet/namingsystem-identifier-type|6.0.0-ballot3"/> </binding> </parameter> <parameter> <name value="date"/> <use value="in"/> <min value="0"/> <max value="1"/> <documentation value="If specified, the operation will indicate what the preferred identifier was on the specified date. If not specified, the operation will provide the preferred identifier as of 'now'"/> <type value="dateTime"/> </parameter> <parameter> <name value="result"/> <use value="out"/> <min value="1"/> <max value="1"/> <documentation value="OIDs are return as plain OIDs (not the URI form)."/> <type value="string"/> </parameter> </ OperationDefinition >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
R5
hl7.fhir.core#5.0.0
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Sun,
Mar
26,
2023
15:25+1100.
Mon,
Nov
24,
2025
20:52+0000.
Links:
Search
|
Version
History
|
Contents
|
Glossary
|
QA
|
Compare
to
R4
|
Compare
to
R4B
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change