Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example-vitals-panel.json

Example Observation/vitals-panel (JSON)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Simple Panel of Heart Rate, Repiratory Rate. Blood Pressure and Body Temperature

{
  "resourceType": "Observation",
  "id": "vitals-panel",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/vitalsigns"
    ]

  "resourceType" : "Observation",
  "id" : "vitals-panel",
  "meta" : {
    "profile" : ["http://hl7.org/fhir/StructureDefinition/vitalsigns"]

  },
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: vitals-panel</p><p><b>meta</b>: </p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span>(Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})</span></p><p><b>code</b>: Vital signs Panel <span>(Details : {LOINC code '85353-1' = 'Vital signs, weight, height, head circumference, oxygen saturation &amp; BMI panel', given as 'Vital signs, weight, height, head circumference, oxygen saturation and BMI panel'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 02/07/1999</p><p><b>hasMember</b>: </p><ul><li><a>Respiratory Rate</a></li><li><a>Heart Rate</a></li><li><a>Blood Pressure</a></li><li><a>Body Temperature</a></li></ul></div>"

  "status" : "final",
  "category" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/observation-category",
      "code" : "vital-signs",
      "display" : "Vital Signs"
    }],
    "text" : "Vital Signs"
  }],
  "code" : {
    "coding" : [{
      "system" : "http://loinc.org",
      "code" : "85353-1",
      "display" : "Vital signs, weight, height, head circumference, oxygen saturation and BMI panel"
    }],
    "text" : "Vital signs Panel"

  },
  "status": "final",
  "category": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/observation-category",
          "code": "vital-signs",
          "display": "Vital Signs"
        }
      ],
      "text": "Vital Signs"
    }
  ],
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "85353-1",
        "display": "Vital signs, weight, height, head circumference, oxygen saturation and BMI panel"
      }
    ],
    "text": "Vital signs Panel"

  "subject" : {
    "reference" : "Patient/example"

  },
  "subject": {
    "reference": "Patient/example"

  "effectiveDateTime" : "1999-07-02",
  "hasMember" : [{
    "reference" : "Observation/respiratory-rate",
    "display" : "Respiratory Rate"

  },
  "effectiveDateTime": "1999-07-02",
  "hasMember": [
    {
      "reference": "Observation/respiratory-rate",
      "display": "Respiratory Rate"
    },
    {
      "reference": "Observation/heart-rate",
      "display": "Heart Rate"
    },
    {
      "reference": "Observation/blood-pressure",
      "display": "Blood Pressure"
    },
    {
      "reference": "Observation/body-temperature",
      "display": "Body Temperature"
    }
  ]

  {
    "reference" : "Observation/heart-rate",
    "display" : "Heart Rate"
  },
  {
    "reference" : "Observation/blood-pressure",
    "display" : "Blood Pressure"
  },
  {
    "reference" : "Observation/body-temperature",
    "display" : "Body Temperature"
  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.