Diagnostics
This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v4.0.1:
R4
-
Mixed
Normative
and
STU
)
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative | Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification )
Specimen Reject Example
@prefix fhir: <http://hl7.org/fhir/> .@prefix loinc: <http://loinc.org/rdf#> .@prefix loinc: <https://loinc.org/rdf/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource -------------------------------------------------------------------<http://hl7.org/fhir/Observation/unsat> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "unsat"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = 'Specimen unsatisfactory for evaluation', given as 'Specimen unsatisfactory for evaluation'})</span></p><p><b>note</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>6.2 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>" ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.use [ fhir:value "official" ]; fhir:Identifier.system [ fhir:value "http://www.bmc.nl/zorgportal/identifiers/observations" ]; fhir:Identifier.value [ fhir:value "6323" ] ]; fhir:Observation.status [ fhir:value "cancelled"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; a loinc:15074-8; fhir:Coding.system [ fhir:value "http://loinc.org" ]; fhir:Coding.code [ fhir:value "15074-8" ]; fhir:Coding.display [ fhir:value "Glucose [Moles/volume] in Blood" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/f001>; fhir:Reference.reference [ fhir:value "Patient/f001" ]; fhir:Reference.display [ fhir:value "P. van de Heuvel" ] ]; fhir:Observation.effectivePeriod [ fhir:Period.start [ fhir:value "2013-04-02T09:30:10+01:00"^^xsd:dateTime ]; fhir:Period.end [ fhir:value "2013-04-05T09:30:10+01:00"^^xsd:dateTime ] ]; fhir:Observation.issued [ fhir:value "2013-04-03T15:30:10+01:00"^^xsd:dateTime]; fhir:Observation.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/f005>; fhir:Reference.reference [ fhir:value "Practitioner/f005" ]; fhir:Reference.display [ fhir:value "A. Langeveld" ] ]; fhir:Observation.dataAbsentReason [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:125154007; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "125154007" ]; fhir:Coding.display [ fhir:value "Specimen unsatisfactory for evaluation" ] ] ]; fhir:Observation.note [ fhir:index 0; fhir:Annotation.text [ fhir:value "Tube broken in transit and sample leaked" ] ]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "3.1"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "6.2"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ]<http://hl7.org/fhir/Observation/unsat> a fhir:Observation ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "unsat"] ; # fhir:identifier ( [ fhir:use [ fhir:v "official" ] ; fhir:system [ fhir:v "http://www.bmc.nl/zorgportal/identifiers/observations"^^xsd:anyURI ; fhir:l <http://www.bmc.nl/zorgportal/identifiers/observations> ] ; fhir:value [ fhir:v "6323" ] ] ) ; # urn:oid:2.16.840.1.113883.4.642.1.7 , 2.16.840.1.113883.4.642.1.118 fhir:status [ fhir:v "cancelled"] ; # fhir:code [ fhir:coding ( [ a loinc:15074-8 ; fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ; fhir:l <http://loinc.org> ] ; fhir:code [ fhir:v "15074-8" ] ; fhir:display [ fhir:v "Glucose [Moles/volume] in Blood" ] ] ) ] ; # fhir:subject [ fhir:l <http://hl7.org/fhir/Patient/f001> ; fhir:reference [ fhir:v "Patient/f001" ] ; fhir:display [ fhir:v "P. van de Heuvel" ] ] ; # fhir:effective [ a fhir:DateTime ; fhir:v "2013-04-02T09:30:10+01:00"^^xsd:dateTime ] ; # fhir:issued [ fhir:v "2013-04-03T15:30:10+01:00"^^xsd:dateTime] ; # fhir:performer ( [ fhir:l <http://hl7.org/fhir/Practitioner/f005> ; fhir:reference [ fhir:v "Practitioner/f005" ] ; fhir:display [ fhir:v "A. Langeveld" ] ] ) ; # fhir:dataAbsentReason [ fhir:coding ( [ a sct:125154007 ; fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ; fhir:l <http://snomed.info/sct> ] ; fhir:code [ fhir:v "125154007" ] ; fhir:display [ fhir:v "Specimen unsatisfactory for evaluation" ] ] ) ] ; # fhir:note ( [ fhir:text [ fhir:v "Tube broken in transit and sample leaked" ] ] ) ; # fhir:referenceRange ( [ fhir:low [ fhir:value [ fhir:v 3.1 ] ; fhir:unit [ fhir:v "mmol/l" ] ; fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ; fhir:l <http://unitsofmeasure.org> ] ; fhir:code [ fhir:v "mmol/L" ] ] ; fhir:high [ fhir:value [ fhir:v 6.2 ] ; fhir:unit [ fhir:v "mmol/l" ] ; fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ; fhir:l <http://unitsofmeasure.org> ] ; fhir:code [ fhir:v "mmol/L" ] ]] .] ) . # <http://hl7.org/fhir/Patient/f001> a fhir:Patient . <http://hl7.org/fhir/Practitioner/f005> a fhir:Practitioner .# - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Observation/unsat.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Observation/unsat.ttl> .# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
4
(Technical
Correction
#1)
(v4.0.1)
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Fri,
Sat,
Nov
1,
2019
09:36+1100.
QA
Page
8,
2025
11:28+0000.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Credits
Glossary
|
QA
|
Compare
to
R3
R4
|
Compare
to
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change