FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f002-excess.xml

Example Observation/f002 (XML)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Ballot Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw XML ( canonical form ) Jump past Narrative + also see XML Format Specification )

Real-world patient -base excess (id = "f002")

(Details : {LOINC code '11555-0' = 'Base excess in Blood by calculation', given as 'Base excess in Blood by calculation'})
<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">  <id value="f002"/>   <!--    urn:oid:2.16.840.1.113883.4.642.1.7    -->  <!--    2.16.840.1.113883.4.642.1.118    -->  <identifier>     <use value="official"/>     <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/>     <value value="6324"/>   </identifier>   <status value="final"/>   <code>     <coding>       <system value="http://loinc.org"/>       <code value="11555-0"/>       <display value="Base excess in Blood by calculation"/>     </coding>   </code>   <subject>     <reference value="Patient/f001"/>     <display value="P. van de Heuvel"/>   </subject>   <effectiveDateTime value="2013-04-02T10:30:10+01:00"/>   <issued value="2013-04-03T15:30:10+01:00"/>   <performer>     <reference value="Practitioner/f005"/>     <display value="A. Langeveld"/>   </performer>   <valueQuantity>     <value value="12.6"/>     <unit value="mmol/l"/>     <system value="http://unitsofmeasure.org"/>     <code value="mmol/L"/>   </valueQuantity>   <interpretation>     <coding>       <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/>       <code value="H"/>       <display value="High"/>     </coding>   </interpretation>   <referenceRange>     <low>       <value value="7.1"/>       <unit value="mmol/l"/>       <system value="http://unitsofmeasure.org"/>       <code value="mmol/L"/>     </low>     <high>       <value value="11.2"/>       <unit value="mmol/l"/>       <system value="http://unitsofmeasure.org"/>       <code value="mmol/L"/>     </high>   </referenceRange> 


</

Observation

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.