Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f002-excess.json

Example Observation/f002 (JSON)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Real-world patient -base excess

{
  "resourceType": "Observation",
  "id": "f002",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f002</p><p><b>identifier</b>: 6324 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Base excess in Blood by calculation <span>(Details : {LOINC code '11555-0' = 'Base excess in Blood by calculation', given as 'Base excess in Blood by calculation'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 10:30:10 AM --&gt; 05/04/2013 10:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>value</b>: 12.6 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></p><p><b>interpretation</b>: High <span>(Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'H' = 'High', given as 'High'})</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>7.1 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>11.2 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/zorgportal/identifiers/observations",
      "value": "6324"
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "11555-0",
        "display": "Base excess in Blood by calculation"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f001",
    "display": "P. van de Heuvel"

  "resourceType" : "Observation",
  "id" : "f002",
  "identifier" : [{
    "use" : "official",
    "system" : "http://www.bmc.nl/zorgportal/identifiers/observations",
    "value" : "6324"
  }],
  "status" : "final",
  "code" : {
    "coding" : [{
      "system" : "http://loinc.org",
      "code" : "11555-0",
      "display" : "Base excess in Blood by calculation"
    }]

  },
  "effectivePeriod": {
    "start": "2013-04-02T10:30:10+01:00",
    "end": "2013-04-05T10:30:10+01:00"

  "subject" : {
    "reference" : "Patient/f001",
    "display" : "P. van de Heuvel"

  },
  "issued": "2013-04-03T15:30:10+01:00",
  "performer": [
    {
      "reference": "Practitioner/f005",
      "display": "A. Langeveld"
    }
  ],
  "valueQuantity": {
    "value": 12.6,
    "unit": "mmol/l",
    "system": "http://unitsofmeasure.org",
    "code": "mmol/L"

  "effectiveDateTime" : "2013-04-02T10:30:10+01:00",
  "issued" : "2013-04-03T15:30:10+01:00",
  "performer" : [{
    "reference" : "Practitioner/f005",
    "display" : "A. Langeveld"
  }],
  "valueQuantity" : {
    "value" : 12.6,
    "unit" : "mmol/l",
    "system" : "http://unitsofmeasure.org",
    "code" : "mmol/L"

  },
  "interpretation": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
          "code": "H",
          "display": "High"
        }
      ]
    }
  ],
  "referenceRange": [
    {
      "low": {
        "value": 7.1,
        "unit": "mmol/l",
        "system": "http://unitsofmeasure.org",
        "code": "mmol/L"
      },
      "high": {
        "value": 11.2,
        "unit": "mmol/l",
        "system": "http://unitsofmeasure.org",
        "code": "mmol/L"
      }

  "interpretation" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
      "code" : "H",
      "display" : "High"
    }]
  }],
  "referenceRange" : [{
    "low" : {
      "value" : 7.1,
      "unit" : "mmol/l",
      "system" : "http://unitsofmeasure.org",
      "code" : "mmol/L"
    },
    "high" : {
      "value" : 11.2,
      "unit" : "mmol/l",
      "system" : "http://unitsofmeasure.org",
      "code" : "mmol/L"

    }
  ]

  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.