Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4

Observation-example-bgpanel.json

Example Observation/bgpanel (JSON)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

An example of a simple blood typing panel.

{
  "resourceType": "Observation",
  "id": "bgpanel",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: bgpanel</p><p><b>status</b>: final</p><p><b>category</b>: Laboratory <span>(Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'laboratory' = 'Laboratory', given as 'Laboratory'})</span></p><p><b>code</b>: Blood Group Panel <span>(Details : {LOINC code '34532-2' = 'Blood type and Indirect antibody screen panel - Blood', given as ' Blood type and Indirect antibody screen panel - Blood'})</span></p><p><b>subject</b>: <a>Patient/infant</a></p><p><b>effective</b>: 11/03/2018 4:07:54 PM</p><p><b>hasMember</b>: </p><ul><li><a>Observation/bloodgroup</a></li><li><a>Observation/rhstatus</a></li></ul></div>"

  "resourceType" : "Observation",
  "id" : "bgpanel",
  "status" : "final",
  "category" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/observation-category",
      "code" : "laboratory",
      "display" : "Laboratory"
    }],
    "text" : "Laboratory"
  }],
  "code" : {
    "coding" : [{
      "system" : "http://loinc.org",
      "code" : "34532-2",
      "display" : "Blood type and Indirect antibody screen panel - Blood"
    }],
    "text" : "Blood Group Panel"

  },
  "status": "final",
  "category": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/observation-category",
          "code": "laboratory",
          "display": "Laboratory"
        }
      ],
      "text": "Laboratory"
    }
  ],
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "34532-2",
        "display": " Blood type and Indirect antibody screen panel - Blood"
      }
    ],
    "text": "Blood Group Panel"

  "subject" : {
    "reference" : "Patient/infant"

  },
  "subject": {
    "reference": "Patient/infant"

  "effectiveDateTime" : "2018-03-11T16:07:54+00:00",
  "hasMember" : [{
    "reference" : "Observation/bloodgroup"

  },
  "effectiveDateTime": "2018-03-11T16:07:54+00:00",
  "hasMember": [
    {
      "reference": "Observation/bloodgroup"
    },
    {
      "reference": "Observation/rhstatus"
    }
  ]

  {
    "reference" : "Observation/rhstatus"
  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.