FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationrequest0314.json

Example MedicationRequest/medrx0314 (JSON)

Maturity Level : N/A
Responsible Owner: Pharmacy Work Group Ballot Standards Status : Informative Compartments : Encounter , Group , Patient , Practitioner

Raw JSON ( canonical form + also see JSON Format Specification )

Order Request - Levothyroxine - completed with reasonCode, dosageInstructions and dispenseRequest

{
  "resourceType": "MedicationRequest",
  "id": "medrx0314",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medrx0314</p><p><b>identifier</b>: 12345689 (OFFICIAL)</p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>priority</b>: routine</p><p><b>medication</b>: Levothyroxine Sodium 75micrograms tablet (product) <span>(Details : {SNOMED CT code '376988009' = 'Levothyroxine sodium 75micrograms tablet', given as 'Levothyroxine Sodium 75micrograms tablet (product)'})</span></p><p><b>subject</b>: <a>Donald Duck</a></p><p><b>authoredOn</b>: 15/01/2015</p><h3>Requesters</h3><table><tr><td>-</td><td><b>Agent</b></td><td><b>OnBehalfOf</b></td></tr><tr><td>*</td><td><a>Patrick Pump</a></td><td><a>Organization/f002</a></td></tr></table><p><b>reasonCode</b>: Hypothyroidism (disorder) <span>(Details : {SNOMED CT code '40930008' = 'Hypothyroidism', given as 'Hypothyroidism (disorder)'})</span></p><p><b>dosageInstruction</b>: </p><h3>DispenseRequests</h3><table><tr><td>-</td><td><b>ValidityPeriod</b></td><td><b>Quantity</b></td><td><b>ExpectedSupplyDuration</b></td></tr><tr><td>*</td><td>15/01/2015 --&gt; 15/01/2016</td><td>100 Tab<span> (Details: http://hl7.org/fhir/v3/orderableDrugForm code Tab = 'Tab')</span></td><td>30 days<span> (Details: UCUM code d = 'd')</span></td></tr></table></div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/portal/prescriptions",
      "value": "12345689"

  "resourceType" : "MedicationRequest",
  "id" : "medrx0314",
  "identifier" : [{
    "use" : "official",
    "system" : "http://www.bmc.nl/portal/prescriptions",
    "value" : "12345689"
  }],
  "status" : "completed",
  "intent" : "order",
  "priority" : "routine",
  "medication" : {
    "concept" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "376988009",
        "display" : "Product containing precisely levothyroxine sodium 75 microgram/1 each conventional release oral tablet (clinical drug)"
      }]

    }
  ],
  "status": "completed",
  "intent": "order",
  "priority": "routine",
  "medicationCodeableConcept": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "376988009",
        "display": "Levothyroxine Sodium 75micrograms tablet (product)"
      }
    ]

  },
  "subject": {
    "reference": "Patient/pat1",
    "display": "Donald Duck"

  "subject" : {
    "reference" : "Patient/pat1",
    "display" : "Donald Duck"

  },
  "authoredOn": "2015-01-15",
  "requester": {
    "agent": {
      "reference": "Practitioner/f007",
      "display": "Patrick Pump"
    },
    "onBehalfOf": {
      "reference": "Organization/f002"
    }

  "authoredOn" : "2015-01-15",
  "requester" : {
    "reference" : "Practitioner/f007",
    "display" : "Patrick Pump"

  },
  "reasonCode": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "40930008",
          "display": "Hypothyroidism (disorder)"
        }
      ]

  "reason" : [{
    "concept" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "40930008",
        "display" : "Hypothyroidism (disorder)"
      }]

    }
  ],
  "dosageInstruction": [
    {
      "sequence": 1,
      "text": "75mcg daily",
      "timing": {
        "repeat": {
          "frequency": 1,
          "period": 1,
          "periodUnit": "d"
        }
      },
      "route": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "26643006",
            "display": "Oral Route (qualifier value)"
          }
        ]

  }],
  "dosageInstruction" : [{
    "sequence" : 1,
    "text" : "75mcg daily",
    "timing" : {
      "repeat" : {
        "frequency" : 1,
        "period" : 1,
        "periodUnit" : "d"
      }
    },
    "route" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "26643006",
        "display" : "Oral Route (qualifier value)"
      }]
    },
    "doseAndRate" : [{
      "type" : {
        "coding" : [{
          "system" : "http://terminology.hl7.org/CodeSystem/dose-rate-type",
          "code" : "ordered",
          "display" : "Ordered"
        }]

      },
      "doseQuantity": {
        "value": 75,
        "unit": "mcg",
        "system": "http://unitsofmeasure.org",
        "code": "mcg"

      "doseQuantity" : {
        "value" : 75,
        "unit" : "mcg",
        "system" : "http://unitsofmeasure.org",
        "code" : "ug"

      }
    }
  ],
  "dispenseRequest": {
    "validityPeriod": {
      "start": "2015-01-15",
      "end": "2016-01-15"

    }]
  }],
  "dispenseRequest" : {
    "validityPeriod" : {
      "start" : "2015-01-15",
      "end" : "2016-01-15"

    },
    "quantity": {
      "value": 100,
      "unit": "Tab",
      "system": "http://hl7.org/fhir/v3/orderableDrugForm",
      "code": "Tab"

    "quantity" : {
      "value" : 100,
      "unit" : "Tab",
      "system" : "http://terminology.hl7.org/CodeSystem/v3-orderableDrugForm",
      "code" : "TAB"

    },
    "expectedSupplyDuration": {
      "value": 30,
      "unit": "days",
      "system": "http://unitsofmeasure.org",
      "code": "d"

    "expectedSupplyDuration" : {
      "value" : 30,
      "unit" : "days",
      "system" : "http://unitsofmeasure.org",
      "code" : "d"

    }
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.