FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationadministration0308.json

Example MedicationAdministration/medadmin0308 (JSON)

Maturity Level : N/A
Responsible Owner: Pharmacy Work Group Ballot Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Subcutaneous Injection - Insulin - Lantus

{
  "resourceType": "MedicationAdministration",
  "id": "medadmin0308",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medadmin0308</p><p><b>status</b>: completed</p><p><b>medication</b>: Lantus 100 unit/ml injectable solution <span>(Details : {RxNorm code '285018' = '285018', given as 'Lantus 100 unit/ml injectable solution'})</span></p><p><b>subject</b>: <a>Donald Duck</a></p><p><b>effective</b>: 15/01/2015 4:30:00 AM --&gt; 15/01/2015 2:30:00 PM</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Patrick Pump</a></td></tr></table><p><b>prescription</b>: <a>MedicationRequest/medrx0320</a></p><h3>Dosages</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Route</b></td><td><b>Dose</b></td></tr><tr><td>*</td><td>20 Units SC before breakfast</td><td>Subcutaneous (qualifier value) <span>(Details : {SNOMED CT code '263887005' = 'Subcutaneous', given as 'Subcutaneous (qualifier value)'})</span></td><td>20 U<span> (Details: UCUM code U = 'U')</span></td></tr></table></div>"
  },
  "status": "completed",
  "medicationCodeableConcept": {
    "coding": [
      {
        "system": "http://www.nlm.nih.gov/research/umls/rxnorm",
        "code": "285018",
        "display": "Lantus 100 unit/ml injectable solution"
      }
    ]

  "resourceType" : "MedicationAdministration",
  "id" : "medadmin0308",
  "status" : "completed",
  "medication" : {
    "concept" : {
      "coding" : [{
        "system" : "http://www.nlm.nih.gov/research/umls/rxnorm",
        "code" : "285018",
        "display" : "insulin glargine 100 UNT/ML Injectable Solution [Lantus]"
      }]
    }

  },
  "subject": {
    "reference": "Patient/pat1",
    "display": "Donald Duck"

  "subject" : {
    "reference" : "Patient/pat1",
    "display" : "Donald Duck"

  },
  "effectivePeriod": {
    "start": "2015-01-15T04:30:00+01:00",
    "end": "2015-01-15T14:30:00+01:00"

  "occurrencePeriod" : {
    "start" : "2015-01-15T04:30:00+01:00",
    "end" : "2015-01-15T14:30:00+01:00"

  },
  "performer": [
    {
      "actor": {
        "reference": "Practitioner/f007",
        "display": "Patrick Pump"

  "performer" : [{
    "actor" : {
      "reference" : {
        "reference" : "Practitioner/f007",
        "display" : "Patrick Pump"

      }
    }
  ],
  "prescription": {
    "reference": "MedicationRequest/medrx0320"

  }],
  "request" : {
    "reference" : "MedicationRequest/medrx0320"

  },
  "dosage": {
    "text": "20 Units SC before breakfast",
    "route": {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "263887005",
          "display": "Subcutaneous (qualifier value)"
        }
      ]

  "dosage" : {
    "text" : "20 Units SC before breakfast",
    "route" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "263887005",
        "display" : "Subcutaneous (qualifier value)"
      }]

    },
    "dose": {
      "value": 20,
      "unit": "U",
      "system": "http://unitsofmeasure.org",
      "code": "U"

    "dose" : {
      "value" : 20,
      "unit" : "U",
      "system" : "http://unitsofmeasure.org",
      "code" : "U"

    }
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.