R3
R2
Responsible
Owner:
Imaging
Integration
Work
Group
|
|
Security Category : Patient | Compartments : Group , Patient |
Representation
of
the
content
produced
in
a
DICOM
imaging
study.
A
study
comprises
a
set
of
series,
each
of
which
includes
a
set
of
Service-Object
Pair
Instances
(SOP
Instances
-
images
or
other
data)
acquired
or
produced
in
a
common
context.
A
series
is
of
only
one
modality
(e.g.
X-ray,
CT,
MR,
ultrasound),
but
a
study
may
can
have
multiple
series
of
different
modalities.
modality
values.
The ImagingStudy resource provides information on available imaging data.
An
ImagingStudy
provides
information
on
a
single
DICOM
imaging
study,
and
the
series
and
imaging
objects
in
that
study.
It
also
provides
information
on
how
to
retrieve
that
information
(in
a
native
DICOM
format,
or
in
a
rendered
format,
such
as
JPEG).
ImagingStudy
is
used
to
make
available
information
about
all
parts
of
a
single
DICOM
study.
This
resource
provides
mappings
of
its
elements
to
DICOM
attributes.
DICOM
attributes
are
identified
by
a
32-bit
tag,
presented
in
canonical
form
as
two
four-digit
hexadecimal
values
within
parentheses
and
separated
by
a
comma,
e.g.
(0008,103E).
The
name
and
value
representation
(data
type)
of
each
attribute
can
be
found
in
DICOM
Part
6
Data
Dictionary
.
The
use
of
the
attributes
in
the
context
of
information
objects,
including
detailed
description
of
use,
can
be
found
in
DICOM
Part
3
Information
Object
Definitions
.
Attributes
used
in
the
DICOM
query
information
models,
such
as
"Number
of
Instances
in
Study",
can
be
found
in
DICOM
Part
4
Annex
C
.
ImagingStudy
provides
access
to
significant
DICOM
information
but
will
only
eliminate
the
need
for
DICOM
query
(e.g.,
QIDO-RS)
a
DICOMweb
search
transaction)
in
the
simplest
cases.
The
DICOM
instances
are
not
stored
in
the
ImagingStudy
resource;
use
of
a
DICOM
WADO-RS
server
or
other
storage
mechanism
service
is
needed.
needed
(e.g.,
a
DICOMweb
retrieve
transaction).
An
One
ImagingStudy
SHALL
reference
one
DICOM
Study,
and
MAY
reference
a
subset
of
that
Study.
More
than
one
ImagingStudy
MAY
reference
the
same
DICOM
Study
or
different
subsets
of
This
resource
can
change
as
additional
information
is
added
to
the
same
related
DICOM
Study.
See notes for guidance on how imaging study element values can be populated and when imaging studies are typically created and updated .
Use
the
The
ImagingStudy
resource
is
used
to
store
details
of
an
entire
DICOM
Study
and
associated
information.
its
relationships
to
other
resources,
such
as
Patient
,
ServiceRequest
,
and
Encounter
.
Use
the
DocumentReference
The
ImagingSelection
resource
is
used
to
store
non-DICOM
images,
video,
or
audio
with
relevant
metadata.
Use
the
Binary
reference
to
a
subset
of
a
study.
Instances
of
this
resource
are
created
for
specific
clinical
purposes
and
are
unlikely
to
store
arbitrary
content.
change
once
created.
Use
An
Observation
typically
relates
to
a
set
of
images
in
the
following
ways.
The
DocumentReference
resource
is
used
to
store
non-DICOM
images,
frames
video,
or
other
audio
with
relevant
metadata.
The
DocumentReference
resource
might
be
appropriate
for
including
a
rendered
DICOM
instances.
image
in
cases
where
only
the
image
is
needed
and
not
the
full
image
context.
Structure
| Name | Flags | Card. | Type |
Description
&
Constraints
Filter:
|
|---|---|---|---|---|
|
|
DomainResource |
A
set
of
images
or
image-related
data
produced
in
single
study
+ Rule: series SHALL only be present if an identifier is present with a system of + Rule: At most, a single identifier SHALL be present with a system of urn:dicom:uid + Rule: If numberOfSeries and series are both present, the numberOfSeries value SHALL match the number of series elements + Rule: If numberOfInstances and series.instance are both present, the numberOfInstances value SHALL match the total number of series.instance elements + Rule: If numberOfInstances and series.numberOfInstances are both present, the numberOfInstances value SHALL be the sum of the series.numberOfInstance values. + Rule: For each series element, if numberOfInstances and instance are both present, the numberOfInstances value SHALL match the number of instance elements + Rule: If modality is present, modality SHALL equal all of the distinct values of series.modality Elements defined in Ancestors: id , meta , implicitRules , language , text , contained , extension , modifierExtension |
|
|
Σ C | 0..* | Identifier |
Business
identifier
for
|
|
?! Σ | 1..1 | code |
registered
|
available
|
cancelled
|
entered-in-error
|
unknown
|
inactive
Binding: Imaging Study Status ( Required ) |
|
Σ C | 0..* | CodeableConcept |
The
distinct
values
for
series'
modalities
Binding: Modality
(
Extensible
)
|
|
Σ | 1..1 | Reference ( Patient | Device | Group ) |
Who
or
what
is
the
subject
of
the
study
|
|
Σ | 0..1 | Reference ( Encounter ) |
Encounter
with
which
this
imaging
study
is
associated
|
|
Σ | 0..1 | dateTime |
When
the
study
was
started
|
|
Σ | 0..* |
Reference
(
CarePlan
|
ServiceRequest
|
Appointment
|
|
Fulfills
plan
or
order
|
|
Σ | 0..* | Reference ( Procedure ) |
Imaging
performed
procedure(s)
|
|
Σ | 0..1 | Reference ( Practitioner | PractitionerRole ) |
Referring
physician
|
|
Σ | 0..* | Reference ( Endpoint ) |
Study
access
endpoint
|
|
Σ | 0..1 |
|
Where
imaging
study
occurred
|
|
Σ | 0..* |
CodeableReference
(
|
Why
was
imaging
study
performed?
Binding: |
|
Σ | 0..* |
|
Comments
made
about
the
imaging
study
|
|
Σ | 0..1 |
|
Study
Description
or
Classification
|
|
Σ
C
|
0..1 |
|
Number
of
Study
Related
Series
|
|
Σ C | 0..1 |
|
Number
of
Study
Related
Instances
|
|
Σ C | 0..* | BackboneElement |
The
set
of
|
|
Σ | 1..1 | id |
DICOM
Series
Instance
UID
|
|
Σ | 0..1 | unsignedInt |
Numeric
identifier
of
this
series
|
|
Σ C | 1..1 | CodeableConcept |
The
modality
used
for
this
series
Binding: Modality
(
Extensible
)
|
|
Σ | 0..1 | string |
Series
Description
or
Classification
|
|
Σ C | 0..1 | unsignedInt |
Number
of
Series
Related
Instances
|
|
Σ | 0..* | Reference ( Endpoint ) |
Series
access
endpoint
|
|
Σ | 0..1 | CodeableReference ( BodyStructure ) |
Body
part
examined
Binding: SNOMED CT Body Structures ( Example ) |
|
Σ | 0..* | Reference ( Specimen ) |
Specimen
imaged
|
|
Σ | 0..1 | dateTime |
When
the
series
started
|
|
Σ | 0..* | BackboneElement |
Who
performed
the
series
|
|
Σ | 0..1 | CodeableConcept |
Type
of
performance
Binding: ImagingStudy series performer function ( Extensible ) |
|
Σ | 1..1 | Reference ( Practitioner | PractitionerRole | Organization | CareTeam | Patient | Device | RelatedPerson | HealthcareService ) |
Who
performed
|
|
C | 0..* | BackboneElement |
A
single
SOP
instance
from
the
series
|
|
1..1 | id |
DICOM
SOP
Instance
UID
|
|
|
1..1 |
|
DICOM
class
type
|
|
|
0..1 | unsignedInt |
The
number
of
this
instance
in
the
series
|
|
|
0..1 | string |
Name
or
title
of
the
instance
|
|
Documentation
for
this
format
|
||||
See the Extensions for this resource
UML Diagram ( Legend )
XML Template
<<ImagingStudy xmlns="http://hl7.org/fhir"><!-- from Resource: id, meta, implicitRules, and language --> <!-- from DomainResource: text, contained, extension, and modifierExtension -->
<</identifier> < <</modality><identifier><!-- I 0..* Identifier Business identifier for imaging study --></identifier> <status value="[code]"/><!-- 1..1 registered | available | cancelled | entered-in-error | unknown | inactive --> <modality><!-- I 0..* CodeableConcept The distinct values for series' modalities--></modality> <subject><!-- 1..1 Reference(Device|Group|Patient) Who or what is the subject of the study --></subject>
<</encounter><encounter><!-- 0..1 Reference(Encounter) Encounter with which this imaging study is associated --></encounter> <started value="[dateTime]"/><!-- 0..1 When the study was started --><| </basedOn> <</partOf> <</referrer><basedOn><!-- 0..* Reference(Appointment|CarePlan|ServiceRequest|Task) Fulfills plan or order --></basedOn> <procedure><!-- 0..* Reference(Procedure) Imaging performed procedure(s) --></procedure> <referrer><!-- 0..1 Reference(Practitioner|PractitionerRole) Referring physician --></referrer> <endpoint><!-- 0..* Reference(Endpoint) Study access endpoint --></endpoint>< < <</procedure> <</location> <| </reason> <</note> < < <<location><!-- 0..1 Reference(Location) Where imaging study occurred --></location> <reason><!-- 0..* CodeableReference(Condition|DiagnosticReport|DocumentReference| Observation) Why was imaging study performed? --></reason> <note><!-- 0..* Annotation Comments made about the imaging study --></note> <description value="[string]"/><!-- 0..1 Study Description or Classification --> <numberOfSeries value="[unsignedInt]"/><!-- I 0..1 Number of Study Related Series --> <numberOfInstances value="[unsignedInt]"/><!-- I 0..1 Number of Study Related Instances --> <series> <!-- I 0..* The set of Series belonging to the study --> <uid value="[id]"/><!-- 1..1 DICOM Series Instance UID --> <number value="[unsignedInt]"/><!-- 0..1 Numeric identifier of this series --><</modality> < < <</endpoint> <</bodySite> <</laterality><modality><!-- I 1..1 CodeableConcept The modality used for this series--></modality> <description value="[string]"/><!-- 0..1 Series Description or Classification --> <numberOfInstances value="[unsignedInt]"/><!-- I 0..1 Number of Series Related Instances --> <endpoint><!-- 0..* Reference(Endpoint) Series access endpoint --></endpoint> <bodySite><!-- 0..1 CodeableReference(BodyStructure) Body part examined --></bodySite> <specimen><!-- 0..* Reference(Specimen) Specimen imaged --></specimen> <started value="[dateTime]"/><!-- 0..1 When the series started --> <performer> <!-- 0..* Who performed the series -->
<</function> <| </actor><function><!-- 0..1 CodeableConcept Type of performance --></function> <actor><!-- 1..1 Reference(CareTeam|Device|HealthcareService|Organization| Patient|Practitioner|PractitionerRole|RelatedPerson) Who performed imaging study --></actor> </performer><<instance> <!-- I 0..* A single SOP instance from the series --> <uid value="[id]"/><!-- 1..1 DICOM SOP Instance UID --><</sopClass> < <<sopClass value="[oid]"/><!-- 1..1 DICOM class type --> <number value="[unsignedInt]"/><!-- 0..1 The number of this instance in the series --> <title value="[string]"/><!-- 0..1 Name or title of the instance --> </instance> </series> </ImagingStudy>
JSON Template
{
"resourceType" : "",
"resourceType" : "ImagingStudy",
// from Resource: id, meta, implicitRules, and language
// from DomainResource: text, contained, extension, and modifierExtension
"
"
"
"identifier" : [{ Identifier }], // I Business identifier for imaging study
"status" : "<code>", // R! registered | available | cancelled | entered-in-error | unknown | inactive
"modality" : [{ CodeableConcept }], // I The distinct values for series' modalities
"subject" : { Reference(Device|Group|Patient) }, // R! Who or what is the subject of the study
"
"encounter" : { Reference(Encounter) }, // Encounter with which this imaging study is associated
"started" : "<dateTime>", // When the study was started
"|
"
"
"basedOn" : [{ Reference(Appointment|CarePlan|ServiceRequest|Task) }], // Fulfills plan or order
"procedure" : [{ Reference(Procedure) }], // Imaging performed procedure(s)
"referrer" : { Reference(Practitioner|PractitionerRole) }, // Referring physician
"endpoint" : [{ Reference(Endpoint) }], // Study access endpoint
"
"
"
"
"|
"
"
"
"
"location" : { Reference(Location) }, // Where imaging study occurred
"reason" : [{ CodeableReference(Condition|DiagnosticReport|DocumentReference|
Observation) }], // Why was imaging study performed?
"note" : [{ Annotation }], // Comments made about the imaging study
"description" : "<string>", // Study Description or Classification
"numberOfSeries" : "<unsignedInt>", // I Number of Study Related Series
"numberOfInstances" : "<unsignedInt>", // I Number of Study Related Instances
"series" : [{ // I The set of Series belonging to the study
"uid" : "<id>", // R! DICOM Series Instance UID
"number" : "<unsignedInt>", // Numeric identifier of this series
"
"
"
"
"
"
"modality" : { CodeableConcept }, // I R! The modality used for this series
"description" : "<string>", // Series Description or Classification
"numberOfInstances" : "<unsignedInt>", // I Number of Series Related Instances
"endpoint" : [{ Reference(Endpoint) }], // Series access endpoint
"bodySite" : { CodeableReference(BodyStructure) }, // Body part examined
"specimen" : [{ Reference(Specimen) }], // Specimen imaged
"started" : "<dateTime>", // When the series started
"performer" : [{ // Who performed the series
"
"|
"function" : { CodeableConcept }, // Type of performance
"actor" : { Reference(CareTeam|Device|HealthcareService|Organization|
Patient|Practitioner|PractitionerRole|RelatedPerson) } // R! Who performed imaging study
}],
"
"instance" : [{ // I A single SOP instance from the series
"uid" : "<id>", // R! DICOM SOP Instance UID
"
"
"
"sopClass" : "<oid>", // R! DICOM class type
"number" : "<unsignedInt>", // The number of this instance in the series
"title" : "<string>" // Name or title of the instance
}]
}]
}
Turtle Template
@prefix fhir: <http://hl7.org/fhir/> .![]()
[ a fhir:;[ a fhir:ImagingStudy; fhir:nodeRole fhir:treeRoot; # if this is the parser root# from # from fhir: fhir: fhir:# from Resource: fhir:id, fhir:meta, fhir:implicitRules, and fhir:language # from DomainResource: fhir:text, fhir:contained, fhir:extension, and fhir:modifierExtension fhir:identifier ( [ Identifier ] ... ) ; # 0..* I Business identifier for imaging study fhir:status [ code ] ; # 1..1 registered | available | cancelled | entered-in-error | unknown | inactive fhir:modality ( [ CodeableConcept ] ... ) ; # 0..* I The distinct values for series' modalities fhir:subject [ Reference(Device|Group|Patient) ] ; # 1..1 Who or what is the subject of the studyfhir:fhir:encounter [ Reference(Encounter) ] ; # 0..1 Encounter with which this imaging study is associated fhir:started [ dateTime ] ; # 0..1 When the study was startedfhir: fhir: fhir:fhir:basedOn ( [ Reference(Appointment|CarePlan|ServiceRequest|Task) ] ... ) ; # 0..* Fulfills plan or order fhir:procedure ( [ Reference(Procedure) ] ... ) ; # 0..* Imaging performed procedure(s) fhir:referrer [ Reference(Practitioner|PractitionerRole) ] ; # 0..1 Referring physician fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Study access endpointfhir: fhir: fhir: fhir: fhir: fhir: fhir: fhir: fhir:fhir:location [ Reference(Location) ] ; # 0..1 Where imaging study occurred fhir:reason ( [ CodeableReference(Condition|DiagnosticReport|DocumentReference|Observation) ] ... ) ; # 0..* Why was imaging study performed? fhir:note ( [ Annotation ] ... ) ; # 0..* Comments made about the imaging study fhir:description [ string ] ; # 0..1 Study Description or Classification fhir:numberOfSeries [ unsignedInt ] ; # 0..1 I Number of Study Related Series fhir:numberOfInstances [ unsignedInt ] ; # 0..1 I Number of Study Related Instances fhir:series ( [ # 0..* I The set of Series belonging to the study fhir:uid [ id ] ; # 1..1 DICOM Series Instance UID fhir:number [ unsignedInt ] ; # 0..1 Numeric identifier of this seriesfhir: fhir: fhir: fhir: fhir: fhir:fhir:modality [ CodeableConcept ] ; # 1..1 I The modality used for this series fhir:description [ string ] ; # 0..1 Series Description or Classification fhir:numberOfInstances [ unsignedInt ] ; # 0..1 I Number of Series Related Instances fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Series access endpoint fhir:bodySite [ CodeableReference(BodyStructure) ] ; # 0..1 Body part examined fhir:specimen ( [ Reference(Specimen) ] ... ) ; # 0..* Specimen imaged fhir:started [ dateTime ] ; # 0..1 When the series started fhir:performer ( [ # 0..* Who performed the seriesfhir: fhir:|fhir:function [ CodeableConcept ] ; # 0..1 Type of performance fhir:actor [ Reference(CareTeam|Device|HealthcareService|Organization|Patient|Practitioner| PractitionerRole|RelatedPerson) ] ; # 1..1 Who performed imaging study ] ... ) ;fhir:fhir:instance ( [ # 0..* I A single SOP instance from the series fhir:uid [ id ] ; # 1..1 DICOM SOP Instance UIDfhir: fhir: fhir:fhir:sopClass [ oid ] ; # 1..1 DICOM class type fhir:number [ unsignedInt ] ; # 0..1 The number of this instance in the series fhir:title [ string ] ; # 0..1 Name or title of the instance ] ... ) ; ] ... ) ; ]
Changes from both R4 and R4B
| ImagingStudy | |
| ImagingStudy.status |
|
| ImagingStudy.modality |
|
|
|
|
| ImagingStudy.procedure |
|
| ImagingStudy.reason |
|
| ImagingStudy.series.modality |
|
| ImagingStudy.series.bodySite |
|
|
|
|
|
|
|
| ImagingStudy.interpreter |
|
| ImagingStudy.procedureReference |
|
| ImagingStudy.procedureCode |
|
| ImagingStudy.reasonCode |
|
| ImagingStudy.reasonReference |
|
| ImagingStudy.series.laterality |
|
See the Full Difference for further information
This analysis is available for R4 as XML or JSON and for R4B as XML or JSON .
Structure
| Name | Flags | Card. | Type |
Description
&
Constraints
Filter:
|
|---|---|---|---|---|
|
|
DomainResource |
A
set
of
images
or
image-related
data
produced
in
single
study
+ Rule: series SHALL only be present if an identifier is present with a system of + Rule: At most, a single identifier SHALL be present with a system of urn:dicom:uid + Rule: If numberOfSeries and series are both present, the numberOfSeries value SHALL match the number of series elements + Rule: If numberOfInstances and series.instance are both present, the numberOfInstances value SHALL match the total number of series.instance elements + Rule: If numberOfInstances and series.numberOfInstances are both present, the numberOfInstances value SHALL be the sum of the series.numberOfInstance values. + Rule: For each series element, if numberOfInstances and instance are both present, the numberOfInstances value SHALL match the number of instance elements + Rule: If modality is present, modality SHALL equal all of the distinct values of series.modality Elements defined in Ancestors: id , meta , implicitRules , language , text , contained , extension , modifierExtension |
|
|
Σ C | 0..* | Identifier |
Business
identifier
for
|
|
?! Σ | 1..1 | code |
registered
|
available
|
cancelled
|
entered-in-error
|
unknown
|
inactive
Binding: Imaging Study Status ( Required ) |
|
Σ C | 0..* | CodeableConcept |
The
distinct
values
for
series'
modalities
Binding: Modality
(
Extensible
)
|
|
Σ | 1..1 | Reference ( Patient | Device | Group ) |
Who
or
what
is
the
subject
of
the
study
|
|
Σ | 0..1 | Reference ( Encounter ) |
Encounter
with
which
this
imaging
study
is
associated
|
|
Σ | 0..1 | dateTime |
When
the
study
was
started
|
|
Σ | 0..* |
Reference
(
CarePlan
|
ServiceRequest
|
Appointment
|
|
Fulfills
plan
or
order
|
|
Σ | 0..* | Reference ( Procedure ) |
Imaging
performed
procedure(s)
|
|
Σ | 0..1 | Reference ( Practitioner | PractitionerRole ) |
Referring
physician
|
|
Σ | 0..* | Reference ( Endpoint ) |
Study
access
endpoint
|
|
Σ | 0..1 |
|
Where
imaging
study
occurred
|
|
Σ | 0..* |
CodeableReference
(
|
Why
was
imaging
study
performed?
Binding: |
|
Σ | 0..* |
|
Comments
made
about
the
imaging
study
|
|
Σ | 0..1 |
|
Study
Description
or
Classification
|
|
Σ
C
|
0..1 |
|
Number
of
Study
Related
Series
|
|
Σ C | 0..1 |
|
Number
of
Study
Related
Instances
|
|
Σ C | 0..* | BackboneElement |
The
set
of
|
|
Σ | 1..1 | id |
DICOM
Series
Instance
UID
|
|
Σ | 0..1 | unsignedInt |
Numeric
identifier
of
this
series
|
|
Σ C | 1..1 | CodeableConcept |
The
modality
used
for
this
series
Binding: Modality
(
Extensible
)
|
|
Σ | 0..1 | string |
Series
Description
or
Classification
|
|
Σ C | 0..1 | unsignedInt |
Number
of
Series
Related
Instances
|
|
Σ | 0..* | Reference ( Endpoint ) |
Series
access
endpoint
|
|
Σ | 0..1 | CodeableReference ( BodyStructure ) |
Body
part
examined
Binding: SNOMED CT Body Structures ( Example ) |
|
Σ | 0..* | Reference ( Specimen ) |
Specimen
imaged
|
|
Σ | 0..1 | dateTime |
When
the
series
started
|
|
Σ | 0..* | BackboneElement |
Who
performed
the
series
|
|
Σ | 0..1 | CodeableConcept |
Type
of
performance
Binding: ImagingStudy series performer function ( Extensible ) |
|
Σ | 1..1 | Reference ( Practitioner | PractitionerRole | Organization | CareTeam | Patient | Device | RelatedPerson | HealthcareService ) |
Who
performed
|
|
C | 0..* | BackboneElement |
A
single
SOP
instance
from
the
series
|
|
1..1 | id |
DICOM
SOP
Instance
UID
|
|
|
1..1 |
|
DICOM
class
type
|
|
|
0..1 | unsignedInt |
The
number
of
this
instance
in
the
series
|
|
|
0..1 | string |
Name
or
title
of
the
instance
|
|
Documentation
for
this
format
|
||||
See the Extensions for this resource
XML Template
<<ImagingStudy xmlns="http://hl7.org/fhir"><!-- from Resource: id, meta, implicitRules, and language --> <!-- from DomainResource: text, contained, extension, and modifierExtension -->
<</identifier> < <</modality><identifier><!-- I 0..* Identifier Business identifier for imaging study --></identifier> <status value="[code]"/><!-- 1..1 registered | available | cancelled | entered-in-error | unknown | inactive --> <modality><!-- I 0..* CodeableConcept The distinct values for series' modalities--></modality> <subject><!-- 1..1 Reference(Device|Group|Patient) Who or what is the subject of the study --></subject>
<</encounter><encounter><!-- 0..1 Reference(Encounter) Encounter with which this imaging study is associated --></encounter> <started value="[dateTime]"/><!-- 0..1 When the study was started --><| </basedOn> <</partOf> <</referrer><basedOn><!-- 0..* Reference(Appointment|CarePlan|ServiceRequest|Task) Fulfills plan or order --></basedOn> <procedure><!-- 0..* Reference(Procedure) Imaging performed procedure(s) --></procedure> <referrer><!-- 0..1 Reference(Practitioner|PractitionerRole) Referring physician --></referrer> <endpoint><!-- 0..* Reference(Endpoint) Study access endpoint --></endpoint>< < <</procedure> <</location> <| </reason> <</note> < < <<location><!-- 0..1 Reference(Location) Where imaging study occurred --></location> <reason><!-- 0..* CodeableReference(Condition|DiagnosticReport|DocumentReference| Observation) Why was imaging study performed? --></reason> <note><!-- 0..* Annotation Comments made about the imaging study --></note> <description value="[string]"/><!-- 0..1 Study Description or Classification --> <numberOfSeries value="[unsignedInt]"/><!-- I 0..1 Number of Study Related Series --> <numberOfInstances value="[unsignedInt]"/><!-- I 0..1 Number of Study Related Instances --> <series> <!-- I 0..* The set of Series belonging to the study --> <uid value="[id]"/><!-- 1..1 DICOM Series Instance UID --> <number value="[unsignedInt]"/><!-- 0..1 Numeric identifier of this series --><</modality> < < <</endpoint> <</bodySite> <</laterality><modality><!-- I 1..1 CodeableConcept The modality used for this series--></modality> <description value="[string]"/><!-- 0..1 Series Description or Classification --> <numberOfInstances value="[unsignedInt]"/><!-- I 0..1 Number of Series Related Instances --> <endpoint><!-- 0..* Reference(Endpoint) Series access endpoint --></endpoint> <bodySite><!-- 0..1 CodeableReference(BodyStructure) Body part examined --></bodySite> <specimen><!-- 0..* Reference(Specimen) Specimen imaged --></specimen> <started value="[dateTime]"/><!-- 0..1 When the series started --> <performer> <!-- 0..* Who performed the series -->
<</function> <| </actor><function><!-- 0..1 CodeableConcept Type of performance --></function> <actor><!-- 1..1 Reference(CareTeam|Device|HealthcareService|Organization| Patient|Practitioner|PractitionerRole|RelatedPerson) Who performed imaging study --></actor> </performer><<instance> <!-- I 0..* A single SOP instance from the series --> <uid value="[id]"/><!-- 1..1 DICOM SOP Instance UID --><</sopClass> < <<sopClass value="[oid]"/><!-- 1..1 DICOM class type --> <number value="[unsignedInt]"/><!-- 0..1 The number of this instance in the series --> <title value="[string]"/><!-- 0..1 Name or title of the instance --> </instance> </series> </ImagingStudy>
JSON Template
{
"resourceType" : "",
"resourceType" : "ImagingStudy",
// from Resource: id, meta, implicitRules, and language
// from DomainResource: text, contained, extension, and modifierExtension
"
"
"
"identifier" : [{ Identifier }], // I Business identifier for imaging study
"status" : "<code>", // R! registered | available | cancelled | entered-in-error | unknown | inactive
"modality" : [{ CodeableConcept }], // I The distinct values for series' modalities
"subject" : { Reference(Device|Group|Patient) }, // R! Who or what is the subject of the study
"
"encounter" : { Reference(Encounter) }, // Encounter with which this imaging study is associated
"started" : "<dateTime>", // When the study was started
"|
"
"
"basedOn" : [{ Reference(Appointment|CarePlan|ServiceRequest|Task) }], // Fulfills plan or order
"procedure" : [{ Reference(Procedure) }], // Imaging performed procedure(s)
"referrer" : { Reference(Practitioner|PractitionerRole) }, // Referring physician
"endpoint" : [{ Reference(Endpoint) }], // Study access endpoint
"
"
"
"
"|
"
"
"
"
"location" : { Reference(Location) }, // Where imaging study occurred
"reason" : [{ CodeableReference(Condition|DiagnosticReport|DocumentReference|
Observation) }], // Why was imaging study performed?
"note" : [{ Annotation }], // Comments made about the imaging study
"description" : "<string>", // Study Description or Classification
"numberOfSeries" : "<unsignedInt>", // I Number of Study Related Series
"numberOfInstances" : "<unsignedInt>", // I Number of Study Related Instances
"series" : [{ // I The set of Series belonging to the study
"uid" : "<id>", // R! DICOM Series Instance UID
"number" : "<unsignedInt>", // Numeric identifier of this series
"
"
"
"
"
"
"modality" : { CodeableConcept }, // I R! The modality used for this series
"description" : "<string>", // Series Description or Classification
"numberOfInstances" : "<unsignedInt>", // I Number of Series Related Instances
"endpoint" : [{ Reference(Endpoint) }], // Series access endpoint
"bodySite" : { CodeableReference(BodyStructure) }, // Body part examined
"specimen" : [{ Reference(Specimen) }], // Specimen imaged
"started" : "<dateTime>", // When the series started
"performer" : [{ // Who performed the series
"
"|
"function" : { CodeableConcept }, // Type of performance
"actor" : { Reference(CareTeam|Device|HealthcareService|Organization|
Patient|Practitioner|PractitionerRole|RelatedPerson) } // R! Who performed imaging study
}],
"
"instance" : [{ // I A single SOP instance from the series
"uid" : "<id>", // R! DICOM SOP Instance UID
"
"
"
"sopClass" : "<oid>", // R! DICOM class type
"number" : "<unsignedInt>", // The number of this instance in the series
"title" : "<string>" // Name or title of the instance
}]
}]
}
Turtle Template
@prefix fhir: <http://hl7.org/fhir/> .![]()
[ a fhir:;[ a fhir:ImagingStudy; fhir:nodeRole fhir:treeRoot; # if this is the parser root# from # from fhir: fhir: fhir:# from Resource: fhir:id, fhir:meta, fhir:implicitRules, and fhir:language # from DomainResource: fhir:text, fhir:contained, fhir:extension, and fhir:modifierExtension fhir:identifier ( [ Identifier ] ... ) ; # 0..* I Business identifier for imaging study fhir:status [ code ] ; # 1..1 registered | available | cancelled | entered-in-error | unknown | inactive fhir:modality ( [ CodeableConcept ] ... ) ; # 0..* I The distinct values for series' modalities fhir:subject [ Reference(Device|Group|Patient) ] ; # 1..1 Who or what is the subject of the studyfhir:fhir:encounter [ Reference(Encounter) ] ; # 0..1 Encounter with which this imaging study is associated fhir:started [ dateTime ] ; # 0..1 When the study was startedfhir: fhir: fhir:fhir:basedOn ( [ Reference(Appointment|CarePlan|ServiceRequest|Task) ] ... ) ; # 0..* Fulfills plan or order fhir:procedure ( [ Reference(Procedure) ] ... ) ; # 0..* Imaging performed procedure(s) fhir:referrer [ Reference(Practitioner|PractitionerRole) ] ; # 0..1 Referring physician fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Study access endpointfhir: fhir: fhir: fhir: fhir: fhir: fhir: fhir: fhir:fhir:location [ Reference(Location) ] ; # 0..1 Where imaging study occurred fhir:reason ( [ CodeableReference(Condition|DiagnosticReport|DocumentReference|Observation) ] ... ) ; # 0..* Why was imaging study performed? fhir:note ( [ Annotation ] ... ) ; # 0..* Comments made about the imaging study fhir:description [ string ] ; # 0..1 Study Description or Classification fhir:numberOfSeries [ unsignedInt ] ; # 0..1 I Number of Study Related Series fhir:numberOfInstances [ unsignedInt ] ; # 0..1 I Number of Study Related Instances fhir:series ( [ # 0..* I The set of Series belonging to the study fhir:uid [ id ] ; # 1..1 DICOM Series Instance UID fhir:number [ unsignedInt ] ; # 0..1 Numeric identifier of this seriesfhir: fhir: fhir: fhir: fhir: fhir:fhir:modality [ CodeableConcept ] ; # 1..1 I The modality used for this series fhir:description [ string ] ; # 0..1 Series Description or Classification fhir:numberOfInstances [ unsignedInt ] ; # 0..1 I Number of Series Related Instances fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Series access endpoint fhir:bodySite [ CodeableReference(BodyStructure) ] ; # 0..1 Body part examined fhir:specimen ( [ Reference(Specimen) ] ... ) ; # 0..* Specimen imaged fhir:started [ dateTime ] ; # 0..1 When the series started fhir:performer ( [ # 0..* Who performed the seriesfhir: fhir:|fhir:function [ CodeableConcept ] ; # 0..1 Type of performance fhir:actor [ Reference(CareTeam|Device|HealthcareService|Organization|Patient|Practitioner| PractitionerRole|RelatedPerson) ] ; # 1..1 Who performed imaging study ] ... ) ;fhir:fhir:instance ( [ # 0..* I A single SOP instance from the series fhir:uid [ id ] ; # 1..1 DICOM SOP Instance UIDfhir: fhir: fhir:fhir:sopClass [ oid ] ; # 1..1 DICOM class type fhir:number [ unsignedInt ] ; # 0..1 The number of this instance in the series fhir:title [ string ] ; # 0..1 Name or title of the instance ] ... ) ; ] ... ) ; ]
Changes from both R4 and R4B
| ImagingStudy | |
| ImagingStudy.status |
|
| ImagingStudy.modality |
|
|
|
|
| ImagingStudy.procedure |
|
| ImagingStudy.reason |
|
| ImagingStudy.series.modality |
|
| ImagingStudy.series.bodySite |
|
|
|
|
|
|
|
| ImagingStudy.interpreter |
|
| ImagingStudy.procedureReference |
|
| ImagingStudy.procedureCode |
|
| ImagingStudy.reasonCode |
|
| ImagingStudy.reasonReference |
|
| ImagingStudy.series.laterality |
|
See the Full Difference for further information
This analysis is available for R4 as XML or JSON and for R4B as XML or JSON .
Additional definitions: Master Definition XML + JSON , XML Schema / Schematron + JSON Schema , ShEx (for Turtle ) + see the extensions , the spreadsheet version & the dependency analysis
| Path | ValueSet | Type | Documentation |
|---|---|---|---|
| ImagingStudy.status | ImagingStudyStatus | Required |
The status of the ImagingStudy. |
| ImagingStudy.modality |
Modality
|
Extensible |
Transitive closure of CID 33 Modality |
| ImagingStudy.reason | ProcedureReasonCodes | Example |
This example value set defines the set of codes that can be used to indicate a reason for a procedure. |
| ImagingStudy.series.modality |
Modality
|
Extensible |
Transitive closure of CID 33 Modality |
| ImagingStudy.series.bodySite | SNOMEDCTBodyStructures | Example |
This
value
set
includes
all
codes
from
SNOMED
CT
|
| ImagingStudy.series.performer.function |
|
|
|
| UniqueKey |
| Location | Description | Expression |
ist-1
| Rule | (base) | series SHALL only be present if an identifier is present with a system of urn:dicom:uid | series.exists() implies identifier.where(system = 'urn:dicom:uid').exists() |
ist-2
| Rule | (base) |
At
most,
a
single
identifier
SHALL
be
present
with
a
system
of
| identifier.where(system = 'urn:dicom:uid').count() < 2 |
ist-3
| Rule | (base) | If numberOfSeries and series are both present, the numberOfSeries value SHALL match the number of series elements | numberOfSeries.exists() and series.exists() implies numberOfSeries = series.count() |
ist-4
|
| (base) | If numberOfInstances and series.instance are both present, the numberOfInstances value SHALL match the total number of series.instance elements | numberOfInstances.exists() and series.exists() implies numberOfInstances = series.instance.count() |
ist-5
| Rule | (base) | If numberOfInstances and series.numberOfInstances are both present, the numberOfInstances value SHALL be the sum of the series.numberOfInstance values. | numberOfInstances.exists() and series.numberOfInstances.exists() implies numberOfInstances = series.numberOfInstances.aggregate($total + $this.toInteger(), 0) |
ist-6
| Rule | (base) | For each series element, if numberOfInstances and instance are both present, the numberOfInstances value SHALL match the number of instance elements | series.where(numberOfInstances.empty() or instance.empty() or numberOfInstances = instance.count()).count() = series.count() |
ist-7
| Rule | (base) | If modality is present, modality SHALL equal all of the distinct values of series.modality | modality.exists() implies modality.coding.select(system&'|'&code).trace('r').exclude(series.modality.coding.select(system&'|'&code).trace('c')).empty() and modality.text.exclude(series.modality.text).empty() and series.modality.coding.select(system&'|'&code).trace('r').exclude(modality.coding.select(system&'|'&code).trace('c')).empty() and series.modality.text.exclude(modality.text).empty() |
A referenced DICOM SOP instance could be:
DICOM
Series
Instance
UID
and
SOP
Instance
UID
use
the
id
datatype,
datatype
and
are
encoded
directly.
For
example,
an
image
with
SOP
Instance
UID
of
2.16.124.113543.1154777499.30246.19789.3503430045.1.1
is
encoded
in
ImagingStudy.series.instance.uid
as
“2.16.124.113543.1154777499.30246.19789.3503430045.1.1”
.
The
ImagingStudy’s
ImagingStudy's
DICOM
Study
Instance
UID
is
encoded
in
the
ImagingStudy.identifier
element,
which
is
of
the
Identifier
datatype.
When
encoding
a
DICOM
UID
in
an
Identifier
datatype,
use
the
Identifier
system
of
“urn:dicom:uid”
,
and
prefix
the
UID
value
with
“urn:oid:”
.
Therefore,
an
ImagingStudy
with
DICOM
Study
Instance
UID
of
2.16.124.113543.1154777499.30246.19789.3503430046
is
encoded
as:
"identifier":{
"system":"urn:dicom:uid",
"value":"urn:oid:2.16.124.113543.1154777499.30246.19789.3503430046"
}
The
study
accession
number
can
also
be
is
encoded
as
an
Reference.Identifier
Reference.identifier
element
using
the
ServiceRequest
Reference
type
and
the
identifier
type,
“ACSN”
ACSN
as
follows:
e.g.:
"basedOn": ["reference": { "type": "ServiceRequest", "identifier":{ "type" : { "coding" : [ { "system" : "http://terminology.hl7.org/CodeSystem/v2-0203", "code" : "ACSN" } ] }, "system":"http://ginormoushospital.org/accession", "value":"GH334103" }"reference": { "identifier":{ "type" : { "coding" : [ { "system" : "http://terminology.hl7.org/CodeSystem/v2-0203", "code" : "ACSN" } ] }, "system":"http://ginormoushospital.org/accession", "value":"GH334103" } } ]
The
ImagingStudy.endpoint
elements
and
ImagingStudy.series.endpoint
elements
indicate
network
services
that
can
be
used
to
access
the
studies,
series,
or
and
instances;
for
example,
a
DICOM
WADO-RS
server.
An
ImagingStudy.series.endpoint
of
a
particular
Endpoint.connectionType
provides
that
service
for
that
series,
and
all
contained
instances.
An
ImagingStudy.endpoint
of
a
particular
connection
type
provides
that
service
for
all
series
in
that
study
that
do
not
have
a
specified
Endpoint
of
that
type,
and
their
contained
instances.
That
is,
an
ImagingStudy.series.endpoint
overrides
an
ImagingStudy.endpoint
of
the
same
connection
type.
Systems
can
determine
if
a
particular
study,
series,
or
instance
is
available
or
offline
by
interacting
with
the
endpoint.
Since
each
study,
or
individual
series
of
a
study
can
be
stored
on
different
imaging
archive
servers,
per-series
endpoints
are
required.
For
the
identified
services
and
use
cases,
all
instances
within
a
series
would
be
stored
together,
and
thus
instance-level
endpoints
are
not
defined.
Different
Endpoint
connection
types
may
can
have
different
capabilities,
protocols
or
requirements;
and
requirements.
Furthermore,
the
specified
Endpoint.address
may
require
manipulation.
identifies
the
DICOM
Web
Service
Base
URI
(see
DICOM
PS
3.18
Section
8.2
).
The
URL
needed
to
retrieve
image
data
might
need
to
be
constructed
from
this
base
URL.
See
below
for
the
details
on
use
of
imaging-related
Endpoint
connection
types.
An
Endpoint.connectionType
of
code
dicom-wado-rs
,
system
http://terminology.hl7.org/CodeSystem/endpoint-connection-type
,
identifies
a
DICOM
WADO-RS
service.
The
Endpoint.address
identifies
the
HTTP(S)
service
base
url.
That
is,
only
the
scheme,
authority
and
path
are
included.
Sub-services,
such
as
study
,
shall
not
be
specified.
The
path
shall
not
contain
a
trailing
slash.
The
DICOM
WADO-RS
(Web
Access
to
DICOM
Objects,
RESTful
mode)
service
uses
a
RESTful
approach
to
study,
series,
and
instance
retrieval.
This
service
allows
for
retrieval
of
native
DICOM
SOP
instances,
or
instances
“rendered”
into
other
formats,
including
JPEG
and
MPEG.
The
media
type
of
a
response
is
specified
by
the
request
Accept
header
(preferred);
or,
by
the
accept
query
parameters.
Supported
media
types
depend
on
the
capabilities
of
the
WADO-RS
server
and
the
classification
of
the
instance
as
“single
frame,”
“multi-frame,”
“video,”
“text,”
or
“other.”
The
WADO-RS
service
also
allows
retrieval
of
study
"single
frame",
"multi-frame",
"video",
"text",
or
series
level
information.
"other".
The
path
to
retrieve
a
DICOM
instance
is
constructed
by
appending
the
appropriate
sub-resource
paths
to
the
Endpoint.address
value.
For example, using the following information in a fictional ImagingStudy resource:
“https://pacs.hospital.org/wado-rs”
https://pacs.hospital.org/wado-rs
found
in
an
ImagingStudy.endpoint.address
,
“1.2.250.1.59.40211.12345678.678910”
1.2.250.1.59.40211.12345678.678910
found
in
an
ImagingStudy.identifier
having
Identifier.system
of
“urn:dicom:uid”
,
“1.2.250.1.59.40211.789001276.14556172.67789”
1.2.250.1.59.40211.789001276.14556172.67789
found
in
ImagingStudy.series.uid
,
and
“1.2.250.1.59.40211.2678810.87991027.899772.2”
1.2.250.1.59.40211.2678810.87991027.899772.2
found
in
ImagingStudy.series.instance.uid
https://pacs.hospital.org/wado-rs/studies/1.2.250.1.59.40211.12345678.678910/series/1.2.250.1.59.40211.789001276.14556172.67789/instances/1.2.250.1.59.40211.2678810.87991027.899772.2
Query
parameters
on
the
"rendered"
sub-resource
can
control
other
aspects
of
the
rendering
including:
the
rendered
dimensions,
the
quality
(compression
ratio),
the
region
of
interest
to
render,
the
brightness/contrast
(window
center/width)
adjustments,
and
whether
to
“burn”
patient
or
study
demographics
into
the
rendered
result.
Specific
frames
of
a
multi-frame
instance
may
can
be
retrieved
using
the
frames
sub-resource.
For example, provided the Accept header indicates a preference for image/jpeg, the example above can be extended with parameters that cause a JPEG (rendered to a size of 400 columns by 400 rows) of a region extending from the top-left corner of the original image to 1000 pixels across and 3000 pixels right, to be retrieved (additional sub-resource and parameters emphasized):
https://pacs.hospital.org/wado-rs/studies/1.2.250.1.59.40211.12345678.678910/series/1.2.250.1.59.40211.789001276.14556172.67789/instances/1.2.250.1.59.40211.2678810.87991027.899772.2/rendered?viewport=400,400,0,0,1000,3000
If the specified WADO-RS service supports the DICOMweb thumbnail resource, a representative image of the study can be requested, for example, to display alongside the study. The URL would look as follows:
https://pacs.hospital.org/wado-rs/studies/1.2.250.1.59.40211.12345678.678910/thumbnail
For
further
details
on
DICOM
WADO-RS
capabilities
including
additional
rendering
parameters,
see
DICOM
PS
3.18
Section
10.4
.
An
Endpoint.connectionType
of
code
dicom-wado-uri
,
system
http://terminology.hl7.org/CodeSystem/endpoint-connection-type
,
identifies
a
DICOM
WADO-URI
service.
The
Endpoint.address
identifies
the
HTTP(S)
service
base
url.
That
is,
only
the
scheme,
authority
and
path
are
included.
Neither
a
question
mark
(“?”)
nor
any
query
parameters
shall
be
included.
The
DICOM
WADO-URI
(Web
Access
to
DICOM
Objects,
URI
mode)
service
uses
HTTP
query
parameter
syntax.
This
service
allows
for
retrieval
of
native
DICOM
instances,
or
instances
“rendered”
into
other
formats,
including
JPEG
and
MPEG.
The
media
type
of
a
response
is
specified
by
the
request
Accept
header
(preferred);
or,
by
the
contentType
query
parameter.
Supported
media
types
depend
on
the
classification
of
the
instance
as
“single
frame,”
“multi-frame,”
“video,”
“text,”
"single
frame",
"multi-frame",
"video",
"text",
or
“other.”
"other."
The
query
to
retrieve
a
DICOM
instance
is
constructed
by
appending
the
appropriate
query
parameters
to
the
Endpoint.address
value.
For example, using the following information in a fictional ImagingStudy resource:
“https://pacs.hospital.org/wado-uri”
https://pacs.hospital.org/wado-uri
found
in
an
ImagingStudy.endpoint.address
,
1.2.250.1.59.40211.12345678.678910”
1.2.250.1.59.40211.12345678.678910
found
in
an
ImagingStudy.identifier
having
Identifier.system
of
“urn:dicom:uid”
urn:dicom:uid
,
“1.2.250.1.59.40211.789001276.14556172.67789”
1.2.250.1.59.40211.789001276.14556172.67789
found
in
ImagingStudy.series.uid
,
and
“1.2.250.1.59.40211.2678810.87991027.899772.2”
1.2.250.1.59.40211.2678810.87991027.899772.2
found
in
ImagingStudy.series.instance.uid
https://pacs.hospital.org/wado-uri?requestType=WADO&studyUID=1.2.250.1.59.40211.12345678.678910&seriesUID=1.2.250.1.59.40211.789001276.14556172.67789&objectUID=1.2.250.1.59.40211.2678810.87991027.899772.2
Additional query parameters can control other aspects of the rendering including rendered dimensions, quality (compression ratio), the region of interest within the image to render, brightness/contrast (window center/width) adjustments, whether to “burn” patient or study demographics into the rendered result, and which frame of a multi-frame instance to retrieve.
For example, provided the Accept header indicates a preference for image/jpeg, the example above can be extended with parameters that cause a JPEG thumbnail (100 columns by 100 rows) of the left half of the image to be retrieved (additional parameters emphasized):
https://pacs.hospital.org/wado-uri?requestType=WADO&studyUID=1.2.250.1.59.40211.12345678.678910&seriesUID=1.2.250.1.59.40211.789001276.14556172.67789&objectUID=1.2.250.1.59.40211.2678810.87991027.899772.2&rows=100&columns=100®ion=0,0,0.5,1
Some
imaging
uses
may
might
require
information
beyond
what
is
present
in
an
ImagingStudy
resource.
Many
of
the
DICOM
patient
and
study
level
attributes
are
found
in
the
FHIR
Patient,
Procedure,
or
other
resources
which
are
referenced
from
an
ImagingStudy
instance.
Other
DICOM
content
may
might
be
transformed
into
other
FHIR
resources,
such
as
DiagnosticReports
or
Observations,
which
are
not
directly
referenced,
but
may
can
be
easily
found.
Although
many
ImagingStudy
consumers
are
expected
to
need
only
the
DICOM
information
contained
in
FHIR
resources,
some
may
might
need
additional
DICOM
attributes.
For
these
cases,
which
by
their
nature
involve
more
imaging-aware
consumers,
the
most
flexible
solution
is
to
leverage
the
DICOM
WADO-RS
metadata-only
endpoint
to
retrieve
an
XML
or
JSON
representation
of
the
DICOM
study,
series,
instance,
or
frame
information.
A benefit of using the metadata endpoint in this way is that the ImagingStudy creator does not need to know each of the attributes that each of the (current or future) ImagingStudy consumers is (or will be) interested in.
A client retrieves the following ImagingStudy:
{
"resourceType": "ImagingStudy",
"id": "example-xr",
"identifier": [
{
"use": "official",
"system": "urn:dicom:uid",
"value": "urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430046"
}
],
...
"series": [
{
"uid": "2.16.124.113543.6003.1154777499.30246.19789.3503430045.1",
...
"endpoint": [
{
"reference": "Endpoint/example-wadors"
}
]
...
}
...
]
}
(See Example XR for full example)
The client retrieves the referenced Endpoint (see Example WADO-RS ) and extracts the WADO-RS URL:
https://pacs.hospital.org/wado-rs.
The client uses the WADO-RS URL, the identifier.value and the series.uid to construct a WADO-RS metadata request:
GET https://pacs.hospital.org/wado-rs/studies/2.16.124.113543.6003.1154777499.30246.19789.3503430046/series/2.16.124.113543.6003.1154777499.30246.19789.3503430045.1/metadata HTTP/1.1 Accept: application/dicom+json
The WADO-RS server then returns the complete DICOM metadata for the requested series.
Joe
Angina
complains
of
shortness
of
breath
and
occasional
chest
pain
to
his
primary
care
physician,
Dr.
Pat
Down
at
Local
MultiClinic,
who
orders
a
stress
echocardiogram;
the
order
Note:
reporting
workflow
is
created
as
a
FHIR
Task
resource
to
manage
the
workflow,
with
a
link
to
not
described
in
this
use
case.
subject
is
current
Patient
basedOn
includes
current
ServiceRequest
identifier
is
Study
Instance
UID
endpoint
points
to
image
archive
WADO-RS
service
modality
is
US
modality
is
now
US,KOS
Dr.
Down
meets
again
with
Joe,
and
they
review
the
results
of
the
stress
test.
Joe
has
a
question
about
the
findings
that
the
key
images
in
the
report
do
not
show,
so
Dr.
Down
uses
the
Local
MultiClinic
status=available
subject.identifier=[identifier
for
selected
patient]
ImagingStudy.identifier
)
ImagingStudy.basedOn.identifier
)
ImagingStudy.procedure
)
ImagingStudy.modality
)
ImagingStudy.endpoint
)
pointing
to
Depending
on
the
modality
and
procedure
type,
a
DICOM
study
can
range
from
having
one
or
two
instances
instance
(as
in
many
X-ray
procedures)
to
several
thousand
instances
(for
some
CT
exams).
exams)
or
even
tens
of
thousands
(for
functional
MRI
studies).
The
number
of
series
within
a
study
has
far
less
variability,
and
is
usually
under
twenty,
although
post-processing,
computer-aided
detection,
and
AI
applications
may
could
cause
modest
increases.
An
ImagingStudy
resource
describing
a
large
DICOM
study
would
itself
be
of
significant
size.
Issuing
narrowly-tailored
narrowly
tailored
queries
can
help
a
client
avoid
search
results
containing
many
ImagingStudy
resources.
The
_summary=true
query
parameter
will
omit
several
resource
elements,
including
all
instance-level
elements;
this
can
be
used
to
examine
search
results
before
retrieving
the
full
instances.
If
a
server
limits
the
byte
size
of
search
bundle,
this
may
can
impact
the
number
of
ImagingStudy
resources
returned
per
search
result
page;
a
client
can
use
the
_count
query
parameter
to
influence
the
number
of
resources
per
search
result
page.
When
populating
an
ImagingStudy
resource,
storing
an
update
for
each
DICOM
instance
in
the
study
could
result
in
sending
previously
sent
information
repeatedly--an
issue
that
grows
as
the
study
size
increases.
It
might
also
result
in
a
server
maintaining
thousands
of
versions
of
the
resource.
Repeated,
rapid
updates
of
an
ImagingStudy
may
lead
to
resource
contention.
Although
not
reflected
in
the
ImagingStudy
resource,
the
size
of
an
individual
referenced
instance
may
can
be
anywhere
from
a
few
kilobytes
(a
compressed
256x256
pixel
MR
or
640x480
pixel
ultrasound
image)
to
a
gigabyte
or
more
(for
digital
breast
tomography
imaging).
When
retrieving
the
referenced
content
of
an
ImagingStudy,
applications
can
consider
whether
all
DICOM
methods
to
reduce
transfer
time,
such
as:
The ImagingStudy resource can be hosted by an image archive application — such as a PACS or Vendor-Neutral Archive — or a more general healthcare informatics application such as an EMR. In some cases, it could be hosted in both locations.
However, the image archive is typically the source of truth for the content of the ImagingStudy.
Depending
on
where
the
ImagingStudy
resource
is
hosted,
there
are
needed,
whether
several
available
mechanisms
for
keeping
the
two
applications
consistent.
In this scenario, the image archive:
The image archive could share ImagingStudy information by:
GET
http://example.org/fhir/ImagingStudy?basedOn=ServiceRequest/123&status=available
In this scenario, the image archive:
while the EMR:
The image archive could share ImagingStudy information by:
In this scenario, the image archive:
while the EMR:
Mechanisms
for
ensuring
consistency
between
two
systems
holding
representations
of
the
same
data
are
used
concurrently
still
in
development.
As the image archive is the "source of truth," the above methods might still be applicable. See Provenance resource.
Typically,
an
ImagingStudy
is
a
FHIR
representation
of
imaging
data
that
is
stored
in
a
DICOM
device,
such
as
an
image
archive
(e.g.,
PACS).
The
value
of
the
status
element
reflects
the
status
of
this
representation
and
does
not
necessarily
reflect
the
status
of
either
the
underlying
imaging
data
or
sequentially,
any
ServiceRequest
or
Task
resources
that
resulted
in
the
ImagingStudy
being
created.
In
some
cases,
the
ImagingStudy
could
be
created
before
any
images
have
been
acquired.
In
this
case,
the
.status
will
have
a
value
of
registered
.
After
at
least
some
images
have
been
acquired
and
what
rendering
the
ImagingStudy
has
been
updated
to
reflect
that,
the
ImagingStudy
will
have
a
status
of
available
.
At
this
stage
the
ImagingStudy
can
be
presented
to
viewing
applications.
If
the
ImagingStudy
is
canceled
before
images
are
acquired
its
status
SHOULD
be
set
to
cancelled
.
If
the
ImagingStudy
is
incorrect
-
e.g.,
due
to
images
being
acquired
with
the
wrong
modality
worklist
entry
selected
—
it
might
be
corrected
with
an
update
operation
or
Transfer
Syntax
set
to
entered-in-error
and
replaced
with
a
new
ImagingStudy.
Additional
DICOM
images,
key
object
notes,
etc.
could
be
created
later,
so
a
status
of
complete
is
appropriate
not
meaningful
for
an
ImagingStudy.
For
this
reason,
this
status
is
not
defined
for
an
ImagingStudy.
Any
applications
waiting
for
the
use
case.
completion
of
an
imaging-related
ServiceRequest
or
Task
SHOULD
track
the
progress
of
those
resources
directly.
An ImagingStudy might be created to represent the content of:
The set of ImagingStudy elements is broadly aligned with these three information models.
In DICOM, a Study can be related to two types of "procedures": requested procedures and performed procedures.
In
the
FHIR
model,
"requested
procedures"
are
represented
by
the
ServiceRequest
resource
while
"performed
procedures"
are
represented
by
the
Procedure
resource.
Therefore,
the
requested
procedure
associated
with
a
particular
imaging
study
would
typically
be
encoded
as
the
ServiceRequest
that
the
imaging
study
is
basedOn.
Similarly,
the
performed
procedure
would
be
encoded
as
the
ImagingStudy.procedure
that
the
imaging
study
is
part
of.
Searching
for
an
imaging
study
by
its
requested
procedure
can
be
done
by
including
based-on
as
a
search
parameter,
and
by
its
performed
procedure
by
including
procedure
as
a
search
parameter.
The
series.bodySite
element
can
include
the
laterality
of
the
(possibly
paired)
anatomic
structures
examined
–
e.g.
left
knee,
bilateral
lungs,
etc.
This
can
be
conveyed
in
several
ways:
series.bodySite
contains
an
anatomic
code
that
includes
laterality,
e.g.
"bodySite": {
"concept": {
"coding": [{
"system": "http://snomed.info/sct",
"code": "5951000",
"display": "Left wrist"
}]
}
}
series.bodySite
contains
a
reference
to
a
BodyStructure
resource
whose
includedStructure.structure
element
contains
an
anatomic
code
that
includes
laterality
series.bodySite
contains
a
reference
to
a
BodyStructure
resource
whose
includedStructure
element
includes
a
laterality
value.
See
this
example
BodyStructure
representation
of
the
Left
Wrist,
with
laterality
and
SNOMED
coding
for
anatomical
structure
.Search parameters for this resource. See also the full list of search parameters for this resource , and check the Extensions registry for search parameters on extensions related to this resource. The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.
| Name | Type | Description | Expression | In Common |
| based-on | reference |
The
order
for
the
|
ImagingStudy.basedOn
( Appointment , |
|
| body-site | token | The body site code studied | ImagingStudy.series.bodySite.concept | |
| body-structure | reference | The body structure resource associated with the ImagingStudy | ImagingStudy.series.bodySite.reference | |
| dicom-class |
|
The type of the instance | ImagingStudy.series.instance.sopClass | |
| encounter | reference | The context of the study |
ImagingStudy.encounter
( Encounter ) |
|
| endpoint | reference | The endpoint for the study or series |
ImagingStudy.endpoint
|
ImagingStudy.series.endpoint
( Endpoint ) |
|
| identifier | token | Identifiers for the Study, such as DICOM Study Instance UID | ImagingStudy.identifier |
|
| instance | token | SOP Instance UID for an instance | ImagingStudy.series.instance.uid | |
| modality | token | The modality of the series | ImagingStudy.series.modality | |
| patient | reference | Who the study is about |
ImagingStudy.subject.where(resolve()
is
Patient)
( Patient ) |
|
| performer | reference | The person who performed the study |
ImagingStudy.series.performer.actor
( Practitioner , Organization , CareTeam , Device , Patient , HealthcareService , PractitionerRole , RelatedPerson ) |
|
| procedure |
reference
|
The performed procedure for the study |
ImagingStudy.procedure
( Procedure ) | |
| reason-concept | token | The reason code for the study | ImagingStudy.reason.concept | |
| reason-reference | reference | The resource reference describing the reason for the study | ImagingStudy.reason.reference | |
| referrer | reference | The referring physician |
ImagingStudy.referrer
( Practitioner , PractitionerRole ) |
|
| series | token | DICOM Series Instance UID for a series | ImagingStudy.series.uid | |
| started | date | When the study was started | ImagingStudy.started | |
| status | token | The status of the study | ImagingStudy.status | |
| subject | reference | Who the study is about |
ImagingStudy.subject
( Group , Device , Patient ) |