Publish-box
(todo)
This
is
the
Continuous
Integration
Build
of
FHIR
(will
be
incorrect/inconsistent
at
times).
See
the
Directory
of
published
versions
Example
DocumentReference/1.2.840.11361907579238403408700.3.1.04.19970327150033
(XML)
Raw
XML
(
canonical
form
+
also
see
XML
Format
Specification
)
Jump
past
Narrative
DICOM
Ultrasound
Image
(id
=
"1.2.840.11361907579238403408700.3.1.04.19970327150033")
<?xml version="1.0" encoding="UTF-8"?>
<DocumentReference xmlns="http://hl7.org/fhir">
<id value="1.2.840.11361907579238403408700.3.1.04.19970327150033"/>
<text>
<status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml">
Ultrasound Image on patient "James Chalmers":<br/>
<img alt="WADO reference to image" src="http://imaging.acme.com/wado/server?requestType=WADO&contentType=application%2Fdicom&
studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&seriesUid=1.2.840.113619.2.21.3408.70
0.0.757923840.3.0&objectUid=1.2.840.11361907579238403408700.3.1.04.19970327150033"/>
</div>
</text>
<extension url="http://nema.org/fhir/extensions#0002-0010">
<valueUri value="urn:oid:1.2.840.10008.1.2.1"/>
</extension>
<identifier>
<type>
<text value="accessionNo"/>
</type>
<system value="http://acme-imaging.com/accession/2012"/>
<value value="1234567"/>
</identifier>
<identifier>
<type>
<text value="studyId"/>
</type>
<system value="urn:dicom:uid"/>
<value value="urn:oid:1.2.840.113619.2.21.848.34082.0.538976288.3"/>
</identifier>
<identifier>
<type>
<text value="seriesId"/>
</type>
<system value="urn:dicom:uid"/>
<value value="urn:oid:1.2.840.113619.2.21.3408.700.0.757923840.3.0"/>
</identifier>
<identifier>
<use value="official"/>
<type>
<text value="InstanceUID"/>
</type>
<system value="urn:dicom:uid"/>
<value value="urn:oid:1.2.840.11361907579238403408700.3.1.04.19970327150033"/>
</identifier>
<status value="current"/>
<modality>
<coding>
<system value="http://dicom.nema.org/resources/ontology/DCM"/>
<code value="US"/>
</coding>
</modality>
<subject>
<reference value="Patient/example"/>
</subject>
<event>
<concept>
<coding>
<system value="http://snomed.info/sct"/>
<code value="399067008"/>
<display value="Lateral projection"/>
</coding>
</concept>
</event>
<author>
<display value="G.E. Medical Systems"/>
</author>
<content>
<attachment>
<contentType value="application/dicom"/>
<url value="http://imaging.acme.com/wado/server?requestType=WADO&contentType=application%2Fdicom&
studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&seriesUid=1.2.840.113619.2.21.3408.70
0.0.757923840.3.0&objectUid=1.2.840.11361907579238403408700.3.1.04.19970327150033"/>
<height value="480"/>
<width value="640"/>
</attachment>
</content>
</
DocumentReference
>
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.