FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R4B R4 R3 R2

Extension-patient-nationality.xml

Example DiagnosticReport/f001 (JSON)

Maturity Level : N/A
Patient Administration Responsible Owner: Orders and Observations Work Group Ballot Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner

Raw XML JSON ( canonical form + also see JSON Format Specification )

nationality Real-world patient example

unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. Value of extension - may be a resource or one of a constrained set of the data types (see Extensibility in the spec for list). unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. Value of extension - may be a resource or one of a constrained set of the data types (see Extensibility in the spec for list). The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. Value of extension - may be a resource or one of a constrained set of the data types (see Extensibility in the spec for list). </ StructureDefinition >
{
  "resourceType" : "Bundle",
  "id" : "f001",
  "type" : "collection",
  "entry" : [{
    "fullUrl" : "https://example.com/base/DiagnosticReport/f001",
    "resource" : {
      "resourceType" : "DiagnosticReport",
      "id" : "f001",
      "text" : {
        "status" : "generated",
        "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: DiagnosticReport f001</b></p><a name=\"f001\"> </a><a name=\"hcf001\"> </a><h2><span title=\"Codes:{http://loinc.org 58410-2}\">CBC panel - Blood by Automated count</span> (<span title=\"Codes:{http://snomed.info/sct 252275004}, {http://terminology.hl7.org/CodeSystem/v2-0074 HM}\">Haematology test</span>) </h2><table class=\"grid\"><tr><td>Subject</td><td>Pieter van de Heuvel  Male, DoB: 1944-11-17 ( urn:oid:2.16.840.1.113883.2.4.6.3#?ngen-9?\u00a0(use:\u00a0usual,\u00a0))</td></tr><tr><td>Reported</td><td>2013-05-15T19:32:52+01:00</td></tr><tr><td>Performer</td><td> <a href=\"organization-example-f001-burgers.html\">Burgers University Medical Centre</a></td></tr><tr><td>Identifier</td><td> <code>http://www.bmc.nl/zorgportal/identifiers/reports</code>/nr1239044\u00a0(use:\u00a0official,\u00a0)</td></tr></table><p><b>Report Details</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>Value</b></td><td><b>Reference Range</b></td><td><b>Flags</b></td><td><b>When For</b></td><td><b>Reported</b></td></tr><tr><td><a href=\"observation-example-f001-glucose.html\"><span title=\"Codes:{http://loinc.org 15074-8}\">Glucose [Moles/volume] in Blood</span></a></td><td>6.3 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span></td><td>3.1 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span> - 6.2 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation H}\">High</span></td><td>2013-04-02T09:30:10+01:00</td><td>2013-04-03T15:30:10+01:00</td></tr><tr><td><a href=\"observation-example-f002-excess.html\"><span title=\"Codes:{http://loinc.org 11555-0}\">Base excess in Blood by calculation</span></a></td><td>12.6 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span></td><td>7.1 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span> - 11.2 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemmol/L = 'mmol/L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation H}\">High</span></td><td>2013-04-02T10:30:10+01:00</td><td>2013-04-03T15:30:10+01:00</td></tr><tr><td><a href=\"observation-example-f003-co2.html\"><span title=\"Codes:{http://loinc.org 11557-6}\">Carbon dioxide [Partial pressure] in Blood</span></a></td><td>6.2 kPa<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codekPa = 'kPa')</span></td><td>4.8 kPa<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codekPa = 'kPa')</span> - 6.0 kPa<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codekPa = 'kPa')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation H}\">High</span></td><td>2013-04-02T10:30:10+01:00</td><td>2013-04-03T15:30:10+01:00</td></tr><tr><td><a href=\"observation-example-f004-erythrocyte.html\"><span title=\"Codes:{http://loinc.org 789-8}\">Erythrocytes [#/volume] in Blood by Automated count</span></a></td><td>4.12 10^12/L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  code10*12/L = '10*12/L')</span></td><td><div><p>12-14 y Male: 4.4 - 5.2  x  10^12/L ; 12-14 y Female: 4.2 - 4.8  x  10^12/L ; 15-17 y Male: 4.6 - 5.4  x  10^12/L ; 15-17 y Female: 4.2 - 4.8  x  10^12/L ; 18-64 y Male: 4.6 - 5.4  x  10^12/L ; 18-64 y Female: 4.0 - 4.8  x  10^12/L ; 65-74 y Male: 4.3 - 5.3  x  10^12/L ; 65-74 y Female: 4.1 - 4.9  x  10^12/L</p>\n</div></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation L}\">Low</span></td><td>2013-04-02T10:30:10+01:00</td><td>2013-04-03T15:30:10+01:00</td></tr><tr><td><a href=\"observation-example-f005-hemoglobin.html\"><span title=\"Codes:{http://loinc.org 718-7}\">Hemoglobin [Mass/volume] in Blood</span></a></td><td>7.2 g/dl<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeg/dL = 'g/dL')</span></td><td>7.5 g/dl<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeg/dL = 'g/dL')</span> - 10 g/dl<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeg/dL = 'g/dL')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation L}\">Low</span></td><td>2013-04-05T10:30:10+01:00</td><td>2013-04-05T15:30:10+01:00</td></tr></table><div><p>Core lab</p>\n</div></div>"
      },
      "identifier" : [{
        "use" : "official",
        "system" : "http://www.bmc.nl/zorgportal/identifiers/reports",
        "value" : "nr1239044"
      }],
      "basedOn" : [{
        "reference" : "ServiceRequest/req"
      }],
      "status" : "final",
      "category" : [{
        "coding" : [{
          "system" : "http://snomed.info/sct",
          "code" : "252275004",
          "display" : "Haematology test"
        },
        {
          "system" : "http://terminology.hl7.org/CodeSystem/v2-0074",
          "code" : "HM"
        }]
      }],
      "code" : {
        "coding" : [{
          "system" : "http://loinc.org",
          "code" : "58410-2",
          "display" : "CBC panel - Blood by Automated count"
        }]
      },
      "subject" : {
        "reference" : "Patient/f001",
        "display" : "P. van den Heuvel"
      },
      "issued" : "2013-05-15T19:32:52+01:00",
      "performer" : [{
        "reference" : "Organization/f001",
        "display" : "Burgers University Medical Centre"
      }],
      "result" : [{
        "reference" : "Observation/f001"
      },
      {
        "reference" : "Observation/f002"
      },
      {
        "reference" : "Observation/f003"
      },
      {
        "reference" : "Observation/f004"
      },
      {
        "reference" : "Observation/f005"
      }],
      "conclusion" : "Core lab"
    }
  },
  {
    "fullUrl" : "https://example.com/base/ServiceRequest/req",
    "resource" : {
      "resourceType" : "ServiceRequest",
      "id" : "req",
      "text" : {
        "status" : "extensions",
        "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ServiceRequest req</b></p><a name=\"req\"> </a><a name=\"hcreq\"> </a><p><b>org/bodysitecode</b>: <span title=\"Codes:{http://snomed.info/sct 14975008}\">Forearm structure</span></p><p><b>identifier</b>: <code>http://www.bmc.nl/zorgportal/identifiers/labresults</code>/L2381</p><p><b>status</b>: Active</p><p><b>intent</b>: Original Order</p><h3>Codes</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Concept</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://loinc.org 58410-2}\">CBC panel - Blood by Automated count</span></td></tr></table><p><b>subject</b>: <a href=\"patient-example-f001-pieter.html\">P. van den Heuvel</a></p><p><b>encounter</b>: <a href=\"encounter-example-f001-heart.html\">Encounter: identifier = http://www.amc.nl/zorgportal/identifiers/visits#v1451\u00a0(use:\u00a0official,\u00a0); status = completed; class = ambulatory; priority = Non-urgent cardiological admission; type = Patient-initiated encounter</a></p><p><b>requester</b>: <a href=\"practitioner-example-f001-evdb.html\">E.van den Broek</a></p><p><b>note</b>: </p><blockquote><div><p>patient almost fainted during procedure</p>\n</div></blockquote></div>"
      },
      "extension" : [{
        "url" : "http://example.org/bodysitecode",
        "valueCodeableConcept" : {
          "coding" : [{
            "system" : "http://snomed.info/sct",
            "code" : "14975008",
            "display" : "Forearm structure"
          }]
        }
      }],
      "identifier" : [{
        "system" : "http://www.bmc.nl/zorgportal/identifiers/labresults",
        "value" : "L2381"
      }],
      "status" : "active",
      "intent" : "original-order",
      "code" : {
        "concept" : {
          "coding" : [{
            "system" : "http://loinc.org",
            "code" : "58410-2",
            "display" : "CBC panel - Blood by Automated count"
          }]
        }
      },
      "subject" : {
        "reference" : "Patient/f001",
        "display" : "P. van den Heuvel"
      },
      "encounter" : {
        "reference" : "Encounter/f001"
      },
      "requester" : {
        "reference" : "Practitioner/f001",
        "display" : "E.van den Broek"
      },
      "note" : [{
        "text" : "patient almost fainted during procedure"
      }]
    }
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.