Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4

Devicedefinition-example.json

Example DeviceDefinition/example (JSON)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Not linked to any No defined compartments

Raw JSON ( canonical form + also see JSON Format Specification )

General DeviceDefinition example

{
  "resourceType": "DeviceDefinition",
  "id": "example",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 0</p></div>"

  "resourceType" : "DeviceDefinition",
  "id" : "example",
  "extension" : [{
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode" : "oo"
  }],
  "identifier" : [{
    "value" : "0"
  }],
  "status" : "active",
  "experimental" : true,
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://www.hl7.org/Special/committees/orders"
    }]
  }],
  "deviceName" : [{
    "name" : "Example Device Name",
    "type" : {
      "coding" : [{
        "system" : "http://hl7.org/fhir/device-nametype",
        "code" : "registered-name"
      }]
    }
  }],
  "deviceVersion" : [{
    "type" : {
      "coding" : [{
        "system" : "http://hl7.org/fhir/device-version-type",
        "code" : "hardware"
      }]
    },
    "value" : "v1.2.3"
  }],
  "url" : "http://hl7.org/fhir/DeviceDefinition/example",
  "hasPart" : [{
    "definitionCanonical" : "http://hl7.org/fhir/DeviceDefinition/example-prodspec"
  }],
  "manufacturer" : {
    "reference" : "Organization/example"

  },
  "identifier": [
    {
      "value": "0"

  "modelNumber" : "Model123",
  "partNumber" : "Part456",
  "publisher" : "HL7 International / Orders and Observations",
  "conformsTo" : [{
    "specification" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "528388",
        "display" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM"
      }]
    },
    "version" : ["3.0"],
    "category" : {
      "coding" : [{
        "system" : "http://hl7.org/fhir/device-specification-category",
        "code" : "exchange"
      }]

    }
  ]

  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.