This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v5.0.0:
R5
-
STU
).
This
is
the
current
published
version
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Generated Narrative: Device PhilipsThermometer
identifier
:
System
Identifier:
1C-87-74-FF-FE-00-EC-20,
Identifier/1C-87-74-FF-FE-00-EC-20,
Bluetooth
Address:
1C-87-74-00-EC-20
Address/1C-87-74-00-EC-20
| DeviceIdentifier | Issuer | Jurisdiction | CarrierHRF | EntryType |
| 31368092380192 | http://hl7.org/fhir/NamingSystem/gs1-di | http://hl7.org/fhir/NamingSystem/fda-udi | (01)31368092380192(21)162502000528 |
|
manufacturer : Philips
serialNumber : 162502000528
| Value | Type |
| Philips ear thermometer |
|
modelNumber : DL8740
type
:
MDC_MOC_VMS_MDS_SIMP:
Personal
Health
Device
(
ISO
11073-10101
Health
informatics
-
Point-of-care
#65573
"MDC_MOC_VMS_MDS_SIMP")
versiondeviceVersiontype : MDC_ID_PROD_SPEC_FW: Firmware revision
( ISO 11073-10101 Health informatics - Point-of-care #531976)value : 1.60
versiondeviceVersiontype : MDC_ID_PROD_SPEC_SW: Software revision
( ISO 11073-10101 Health informatics - Point-of-care #531975)value : 1.50
versiondeviceVersiontype : MDC_ID_PROD_SPEC_SW: Hardware revision
( ISO 11073-10101 Health informatics - Point-of-care #531974)value : 1.40
versiondeviceVersiontype : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version
( ISO 11073-10101 Health informatics - Point-of-care #532352)value : 5.1
| Specification | Version |
|
MDC_DEV_SPEC_PROFILE_TEMP:
Thermometer
|
1 |
property
type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list
( ISO 11073-10101 Health informatics - Point-of-care #532353)value : 32776
(ContinuaPAN#32776)
property
type : regulation-status
(ASN1ToHL7#532354.0)value : Device is Regulated
(v2-0136#N)
property
type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol
( ISO 11073-10101 Health informatics - Point-of-care #68220)value : MDC_TIME_SYNC_NONE: No time synchronization
( ISO 11073-10101 Health informatics - Point-of-care #532224)
property
type : mds-time-capab-real-time-clock
(ASN1ToHL7#68219.0)value : real time clock supported
(v2-0136#Y)
property
type : mds-time-capab-set-clock
(ASN1ToHL7#68219.1)value : setting the time supported
(v2-0136#Y)
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.