| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Generated Narrative: Device NoninBlePulseOx
identifier
:
System
Identifier:
74-E8-FF-FE-FF-05-1C-00,
Identifier/74-E8-FF-FE-FF-05-1C-00,
Bluetooth
Address:
00-1C-05-FF-E8-74
Address/00-1C-05-FF-E8-74
| DeviceIdentifier | Issuer | Jurisdiction | CarrierHRF | EntryType |
| 120359741556 | http://hl7.org/fhir/NamingSystem/gs1-di | http://hl7.org/fhir/NamingSystem/fda-udi | (01)120359741556(21)501900083 |
|
manufacturer : Nonin_Medical_Inc.
serialNumber : 501900083
| Value | Type |
| Nonin3230_501900083 |
|
modelNumber : Model 3230
type
:
MDC_MOC_VMS_MDS_SIMP:
Personal
Health
Device
(
ISO
11073-10101
Health
informatics
-
Point-of-care
#65573
"MDC_MOC_VMS_MDS_SIMP")
versiondeviceVersiontype : MDC_ID_PROD_SPEC_FW: Firmware revision
( ISO 11073-10101 Health informatics - Point-of-care #531976)value : r2.1
versiondeviceVersiontype : MDC_ID_PROD_SPEC_SW: Software revision
( ISO 11073-10101 Health informatics - Point-of-care #531975)value : r1.5 9.7
versiondeviceVersiontype : MDC_ID_PROD_SPEC_HW: Hardware revision
( ISO 11073-10101 Health informatics - Point-of-care #531974)value : r1.0
versiondeviceVersiontype : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version
( ISO 11073-10101 Health informatics - Point-of-care #532352)value : 6.0
| Specification | Version |
|
MDC_DEV_SPEC_PROFILE_PULS_OXIM:
Pulse
Oximeter
|
1 |
property
type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list
( ISO 11073-10101 Health informatics - Point-of-care #532353)value : 4
(ContinuaPAN#4)
property
type : regulation-status
(ASN1ToHL7#532354.0)value : Device is Regulated
(v2-0136#N)
property
type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol
( ISO 11073-10101 Health informatics - Point-of-care #68220)value : MDC_TIME_SYNC_NONE: No time synchronization
( ISO 11073-10101 Health informatics - Point-of-care #532224)
property
type : mds-time-capab-real-time-clock
(ASN1ToHL7#68219.0)value : real time clock supported
(v2-0136#Y)
property
type : mds-time-capab-set-clock
(ASN1ToHL7#68219.1)value : setting the time supported
(v2-0136#Y)
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.