Administration
Publish-box
(todo)
This
is
the
Continuous
Integration
Build
of
FHIR
(will
be
incorrect/inconsistent
at
times).
See
the
Directory
of
published
versions
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
Raw XML ( canonical form + also see XML Format Specification )
Bodimetrics (id = "Bodimetrics")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="Bodimetrics"/> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="00-00-00-00-00-00-00-00"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="00-17-E9-54-C8-52"/> </identifier> <udiCarrier> <deviceIdentifier value="102698895442"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)102698895442(21)1607124656"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="BodiMetrics"/> <serialNumber value="1607124656"/> <name> <value value="BM-88 4656"/> <type> <coding> <system value="http://hl7.org/fhir/device-nametype"/> <code value="user-friendly-name"/> </coding> </type> </name> <modelNumber value="6611"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="020008"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="CC"/> </deviceVersion> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528391"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528457"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528390"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528388"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528392"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> </ Device >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Tue,
Apr
1,
Mon,
Nov
10,
2025
12:24+1100.
04:55+0000.
Links:
Search
|
Version
History
|
Contents
|
Glossary
|
QA
|
Compare
to
R4
|
Compare
to
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change