This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v5.0.0:
R5
-
STU
).
This
is
the
current
published
version
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Generated Narrative: Device AndroidGatewayPHG
identifier
:
System
Identifier:
4C-4E-49-12-34-56-FF-FF
Identifier/4C-4E-49-12-34-56-FF-FF
type
:
MDC_MOC_VMS_MDS_AHD:
Continua
compliant
Gateway
(
ISO
11073-10101
Health
informatics
-
Point-of-care
#531981
"MDC_MOC_VMS_MDS_AHD")
| Type | Value |
|
MDC_REG_CERT_DATA_CONTINUA_VERSION:
Continua
version
|
6.0 |
property
type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list
( ISO 11073-10101 Health informatics - Point-of-care #532353)value : 4
(ContinuaPAN#4)
property
type : MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list
( ISO 11073-10101 Health informatics - Point-of-care #532355)value : 0
(ContinuaHFS#0)
property
type : MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list
( ISO 11073-10101 Health informatics - Point-of-care #532355)value : 3
(ContinuaHFS#3)
property
type : MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list
( ISO 11073-10101 Health informatics - Point-of-care #532355)value : 7
(ContinuaHFS#7)
property
type : MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list
( ISO 11073-10101 Health informatics - Point-of-care #532355)value : 2
(ContinuaHFS#2)
property
type : MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list
( ISO 11073-10101 Health informatics - Point-of-care #532355)value : 6
(ContinuaHFS#6)
property
type : regulation-status
(ASN1ToHL7#532354.0)value : Device is Unregulated
(v2-0136#Y)
property
type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol
( ISO 11073-10101 Health informatics - Point-of-care #68220)value : MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization
( ISO 11073-10101 Health informatics - Point-of-care #532226)
property
type : MDC_TIME_SYNC_ACCURACY: unknown code
( ISO 11073-10101 Health informatics - Point-of-care #68221)value : 120000000
( UCUM #us)
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.