Administration
This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v5.0.0:
R5
-
STU
).
This
is
the
current
published
version
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
Raw XML ( canonical form + also see XML Format Specification )
ANDThermometer (id = "ANDThermometer")
<?xml version="1.0" encoding="UTF-8"?>display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%<Device xmlns="http://hl7.org/fhir"> <id value="ANDThermometer"/> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="54-4A-16-FF-FE-32-12-26"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="54-4A-16-32-12-26"/> </identifier> <udiCarrier> <deviceIdentifier value="92677176693286"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)92677176693286(21)5160800011"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="A&D Medical"/> <serialNumber value="5160800011"/> <name> <value value="A&D_UT201BLEA_321226"/> <type> <coding> <system value="http://hl7.org/fhir/device-nametype"/> <code value="user-friendly-name"/> </coding> </type> </name> <modelNumber value="UT-201BLE-A"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531976"/> </coding> <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> </type> <value value="HTP009_137"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="0.00"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="0.00"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532352"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/> </type> <value value="4.1"/> </deviceVersion> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528392"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532353"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN"/> <code value="32776"/> </coding> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="532354.0"/> <display value="regulation-status"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="N"/> </coding> <text value="Device is Regulated"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.0"/> <display value="mds-time-capab-real-time-clock"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="real time clock supported"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.1"/> <display value="mds-time-capab-set-clock"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="setting the time supported"/> </valueCodeableConcept> </property> </ Device >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
R5
hl7.fhir.core#5.0.0
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Sun,
Mar
26,
2023
15:24+1100.
Mon,
Nov
10,
2025
15:21+0000.
Links:
Search
|
Version
History
|
Contents
|
Glossary
|
QA
|
Compare
to
R4
|
Compare
to
R4B
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change