Generated Narrative: Device ANDThermometer

Resource Device "ANDThermometer"

identifier : System Identifier: 54-4A-16-FF-FE-32-12-26, Identifier/54-4A-16-FF-FE-32-12-26, Bluetooth Address: 54-4A-16-32-12-26 Address/54-4A-16-32-12-26

UdiCarriers

- DeviceIdentifier Issuer Jurisdiction CarrierHRF EntryType
* 92677176693286 http://hl7.org/fhir/NamingSystem/gs1-di http://hl7.org/fhir/NamingSystem/fda-udi (01)92677176693286(21)5160800011 unknown Unknown

manufacturer : A&D Medical

serialNumber : 5160800011

Names

- Value Type
* A&D_UT201BLEA_321226 user-friendly-name User Friendly name

modelNumber : UT-201BLE-A

type : MDC_MOC_VMS_MDS_SIMP: Personal Health Device ( ISO 11073-10101 Health informatics - Point-of-care #65573 "MDC_MOC_VMS_MDS_SIMP")

version deviceVersion

type : MDC_ID_PROD_SPEC_FW: Firmware revision ( ISO 11073-10101 Health informatics - Point-of-care #531976)

value : HTP009_137

version deviceVersion

type : MDC_ID_PROD_SPEC_SW: Software revision ( ISO 11073-10101 Health informatics - Point-of-care #531975)

value : 0.00

version deviceVersion

type : MDC_ID_PROD_SPEC_HW: Hardware revision ( ISO 11073-10101 Health informatics - Point-of-care #531974)

value : 0.00

version deviceVersion

type : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version ( ISO 11073-10101 Health informatics - Point-of-care #532352)

value : 4.1

ConformsTos

- Specification Version
* MDC_DEV_SPEC_PROFILE_TEMP: Thermometer ( ISO 11073-10101 Health informatics - Point-of-care #528392) 1

property

type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list ( ISO 11073-10101 Health informatics - Point-of-care #532353)

value : 32776 (ContinuaPAN#32776)

property

type : regulation-status (ASN1ToHL7#532354.0)

value : Device is Regulated (v2-0136#N)

property

type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol ( ISO 11073-10101 Health informatics - Point-of-care #68220)

value : MDC_TIME_SYNC_NONE: No time synchronization ( ISO 11073-10101 Health informatics - Point-of-care #532224)

property

type : mds-time-capab-real-time-clock (ASN1ToHL7#68219.0)

value : real time clock supported (v2-0136#Y)

property

type : mds-time-capab-set-clock (ASN1ToHL7#68219.1)

value : setting the time supported (v2-0136#Y)


 

 