Terminology
This
page
is
part
of
the
FHIR
Specification
(v3.0.2:
STU
3).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
Continuous
Integration
Build
of
available
versions,
see
FHIR
(will
be
incorrect/inconsistent
at
times).
See
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
|
|
|
Raw JSON ( canonical form + also see JSON Format Specification )
Definition
for
Code
System
Procedure
Device
Action
Codes
SystemProcedureDeviceActionCodes
{
"resourceType": "CodeSystem",
"id": "device-action",
"meta": {
"lastUpdated": "2019-10-24T11:53:00+11:00",
"profile": [
"http://hl7.org/fhir/StructureDefinition/shareablecodesystem"
]
"resourceType" : "CodeSystem",
"id" : "device-action",
"meta" : {
"lastUpdated" : "2025-11-08T11:23:29.301+00:00"
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem device-action</b></p><a name=\"device-action\"> </a><a name=\"hcdevice-action\"> </a><p>This case-sensitive code system <code>http://hl7.org/fhir/device-action</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style=\"white-space:nowrap\">implanted<a name=\"device-action-implanted\"> </a></td><td>Implanted</td><td>The device was implanted in the patient during the procedure.</td></tr><tr><td style=\"white-space:nowrap\">explanted<a name=\"device-action-explanted\"> </a></td><td>Explanted</td><td>The device was explanted from the patient during the procedure.</td></tr><tr><td style=\"white-space:nowrap\">manipulated<a name=\"device-action-manipulated\"> </a></td><td>Manipulated</td><td>The device remains in the patient, but its location, settings, or functionality was changed.</td></tr></table></div>"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status",
"valueString": "Informative"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 3
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "pc"
}
],
"url": "http://hl7.org/fhir/device-action",
"identifier": {
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.4.642.1.417"
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "pc"
}],
"url" : "http://hl7.org/fhir/device-action",
"identifier" : [{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.4.426"
},
"version": "3.0.2",
"name": "Procedure Device Action Codes",
"status": "draft",
"experimental": true,
"publisher": "HL7 International - Patient Care WG",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/patientcare/"
}
]
}
],
"description": "Example codes indicating the change that happened to the device during the procedure. Note that these are in no way complete and may not even be appropriate for some uses.",
"copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
"caseSensitive": true,
"valueSet": "http://hl7.org/fhir/ValueSet/device-action",
"content": "complete",
"concept": [
{
"code": "implanted",
"display": "Implanted",
"definition": "The device was implanted in the patient during the procedure."
},
{
"code": "explanted",
"display": "Explanted",
"definition": "The device was explanted from the patient during the procedure."
},
{
"code": "manipulated",
"display": "Manipulated",
"definition": "The device remains in that patient, but its location, settings, or functionality was changed."
}
]
{
"use" : "old",
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.1.417"
},
{
"use" : "old",
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.2.236"
}],
"version" : "6.0.0-ballot3",
"name" : "ProcedureDeviceActionCodes",
"title" : "Procedure Device Action Codes",
"status" : "active",
"experimental" : false,
"publisher" : "HL7 International",
"description" : "Example value set for Procedure Device Action code (what happened to a device during a procedure.",
"jurisdiction" : [{
"coding" : [{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001",
"display" : "World"
}]
}],
"caseSensitive" : true,
"content" : "complete",
"concept" : [{
"code" : "implanted",
"display" : "Implanted",
"definition" : "The device was implanted in the patient during the procedure."
},
{
"code" : "explanted",
"display" : "Explanted",
"definition" : "The device was explanted from the patient during the procedure."
},
{
"code" : "manipulated",
"display" : "Manipulated",
"definition" : "The device remains in the patient, but its location, settings, or functionality was changed."
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
3
(STU;
v3.0.2-11200)
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Thurs,
Oct
24,
2019
11:53+1100.
QA
Page
Sat,
Nov
8,
2025
11:25+0000.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Credits
Glossary
|
QA
|
Compare
to
DSTU2
R4
|
Compare
to
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change