URL | http://hl7.org/fhir/4.0/StructureDefinition/extension-ExampleScenario.identifier |
Version | |
Status | active |
Description | Cross-Version Extension for ExampleScenario.identifier. Valid in versions R2, R3 This is a valid cross-version extension because it's counted as a new element |
Context of Use
This extension may be used in the following contexts:
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Extension | Additional identifier for the example scenario | |
![]() ![]() ![]() | ..0 | |||
![]() ![]() ![]() | 1.. | Identifier | ||
![]() ![]() ![]() | "http://hl7.org/fhir/4.0/StructureDefinition/extension-ExampleScenario.identifier" | |||
![]() |
{ "resourceType" : "StructureDefinition", "id" : "xv-r4-exs.identifier", "url" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-ExampleScenario.identifier", "name" : "XVerExtensionExampleScenario.identifierR4", "title" : "Cross-Version Extension for ExampleScenario.identifier in R4", "status" : "active", "experimental" : false, "publisher" : "Health Level Seven International (FHIR Infrastructure)", "contact" : [{ "telecom" : [{ "system" : "url", "value" : "http://hl7.org/fhir" }] }, { "telecom" : [{ "system" : "url", "value" : "http://www.hl7.org/Special/committees/fiwg/index.cfm" }] }], "description" : "Cross-Version Extension for ExampleScenario.identifier. Valid in versions R2, R3\r\n\r\nThis is a valid cross-version extension because it's counted as a new element", "jurisdiction" : [{ "coding" : [{ "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm", "code" : "001" }] }], "fhirVersion" : "5.0.0", "kind" : "complex-type", "abstract" : false, "context" : [{ "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "3.0" }, { "url" : "endFhirVersion", "valueCode" : "3.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Basic" }, { "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "1.0" }, { "url" : "endFhirVersion", "valueCode" : "1.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Basic" }], "type" : "Extension", "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension", "derivation" : "constraint", "differential" : { "element" : [{ "path" : "Extension", "short" : "Additional identifier for the example scenario", "definition" : "A formal identifier that is used to identify this example scenario when it is represented in other formats, or referenced in a specification, model, design or an instance.", "comment" : "Typically, this is used for identifiers that can go in an HL7 V3 II (instance identifier) data type, and can then identify this example scenario outside of FHIR, where it is not possible to use the logical URI.", "requirements" : "Allows externally provided and/or usable business identifiers to be easily associated with the module.", "min" : 0, "max" : "*", "isModifier" : false, "mapping" : [{ "identity" : "workflow", "map" : "Definition.identifier" }, { "identity" : "w5", "map" : "FiveWs.identifier" }, { "identity" : "objimpl", "map" : "no-gen-base" }] }, { "path" : "Extension.extension", "max" : "0" }, { "path" : "Extension.value[x]", "min" : 1, "type" : [{ "code" : "Identifier" }] }, { "path" : "Extension.url", "fixedUri" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-ExampleScenario.identifier" }] } }